Publicación: Plan de mantenimiento basado en RBI para la caldera de vapor power máster del área de apoyo crítico de una empresa del sector nutracéutico (omega 3)
| dc.contributor.advisor | Diaz Guerrero, Pedro José | |
| dc.contributor.author | Herrera Ortega, Omar Ricardo | |
| dc.contributor.author | Betancourt Alvarez, Jorge Armando | |
| dc.date.accessioned | 2024-03-03T23:57:53Z | |
| dc.date.available | 2018 | |
| dc.date.available | 2024-03-03T23:57:53Z | |
| dc.date.created | 2018 | |
| dc.date.issued | 2018 | |
| dc.description.abstract | La globalización de los mercados nos enseña a ser más competitivos cada día, es por esto que las industrias del sector Nutracéutico donde la competencia es muy alta y los márgenes son muy ajustados se plantean alternativas que permitan la optimización de los costos de producción lo cual le permitirán mantenerse vigentes en el mercado, el presente trabajo plantea mediante el diseño de un Plan de mantenimiento basado en RBI aumentar la confiabilidad y disponibilidad de la caldera de vapor Power Master del área de apoyo crítico del proceso de producción, lo cual impactara de manera positiva los costos de mantenimiento y los costos de producción. Inicialmente haremos una breve reseña del sector Nutracéutico y su organización. Luego se darán conceptos sobre Mantenimiento, Inspección basada en riesgo, ventajas de este tipo de mantenimiento, análisis de falla, análisis de causa raíz, clase y descripción de las calderas de vapor. Con la implementación de la Inspección basada en riesgo se evaluará el nivel de riesgo de este componente, se establecerán las actividades requeridas para detectar el deterioro de este antes que se presente la falla, nos alejaríamos de la inspección basada en el tiempo debido a que se realizarán las inspecciones planeadas que son realmente necesarias disminuyendo el número de inspecciones, realizando paradas de menor tiempo. Para el diseño de este plan se elaborará una matriz de criticidad de equipos basados en la norma API 580, se realizará un análisis FEMA que identifique los modos de falla y los actores que la producen en este componente, se realizara un análisis de esta información y posteriormente se diseñara el plan de inspección basado en RBI y finalmente se establecerán los indicadores de gestión que medirán la efectividad de la caldera de vapor Power Master del área de apoyo crítico. | |
| dc.description.abstractenglish | The globalization of the markets teaches us to be more competitive every day, that is why the industries of the Nutraceutical sector where competition is very high and the margins are very tight consider alternatives that allow the optimization of production costs which will allow to remain valid in the market, the present work raises through the design of a maintenance plan based on RBI increase the reliability and availability of the steam boiler power master of the critical support area of the production, which will positively impact maintenance costs and production costs. Initially we will make a brief overview of the Nutraceutical sector and its organization. Then concepts about Maintenance, Risk-based inspection, advantages of this type of maintenance, failure analysis, root cause analysis, class and description of steam boilers will be given. With this methodology the risk level of this component will be evaluated, the required activities will be established to detect the deterioration of this before the failure occurs, we would move away from the inspection based on the time due to the planned inspections that are carried out. Really necessary by decreasing the number of inspections, making shorter stops. For the design of this plan a criticality matrix of equipment based on the API 580 standard will be elaborated, a FEMA analysis will be carried out to identify the failure modes and the actors that produce it, after this information the inspection plan will be based in RBI and finally, the management indicators that will measure the effectiveness of the Power Master steam boiler in the critical support area will be established. | |
| dc.description.degreelevel | Especialización | |
| dc.description.degreename | Especialista en Gerencia de Mantenimiento | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/37910 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Especialización en Gerencia de Mantenimiento | |
| dc.publisher.school | Escuela de Ingeniería Mecánica | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Inspeccion Basada En Riesgo | |
| dc.subject | Matriz De Criticidad | |
| dc.subject | Caldera De Vapor | |
| dc.subject | Analisis Fema | |
| dc.subject.keyword | Risk Based Inspection | |
| dc.subject.keyword | Criticity Matrix | |
| dc.subject.keyword | Steam Boiler | |
| dc.subject.keyword | Fema Analysis | |
| dc.title | Plan de mantenimiento basado en RBI para la caldera de vapor power máster del área de apoyo crítico de una empresa del sector nutracéutico (omega 3) | |
| dc.title.english | Maintenance plan based on rbi for the power master steam boiler of the critical support area of a nutraceutical sector company (omega 3). | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 587.87 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 250.12 KB
- Formato:
- Adobe Portable Document Format