Publicación: Design and construction of a device that facilitates the stretching of plantar flexors muscles in the therapy of rehabilitation for patients with spastic hemiplegia
| dc.contributor.advisor | Villegas Bermúdez, Diego Fernando | |
| dc.contributor.author | Barragan Parada, Eduardo | |
| dc.contributor.author | Calderon Lesmes, Nathalia Andrea | |
| dc.date.accessioned | 2024-03-04T00:10:27Z | |
| dc.date.available | 2018 | |
| dc.date.available | 2024-03-04T00:10:27Z | |
| dc.date.created | 2018 | |
| dc.date.issued | 2018 | |
| dc.description.abstract | La espasticidad en los músculos plantiflexores como un producto del accidente cerebrovascular (ACV) restringe la movilidad y la independencia de las personas afectadas. Comúnmente, los fisioterapeutas están a cargo de realizar manualmente la terapia de rehabilitación conocida como estiramiento mecánico sostenido, rotando el pie afectado del paciente en el plano sagital. Sin embargo, esto causa un desgaste físico en el profesional porque es un movimiento fatigante. En este artículo, se desarrolla un dispositivo mecánico para implementar esta terapia de rehabilitación de manera más eficiente. El dispositivo consiste en un mecanismo de sin fin-corona que es accionado por una manivela para girar gradualmente una plataforma en el plano sagital del pie afectado, con el fin de lograr la dorsiflexión. El dispositivo tiene un rango de rotación sagital de hasta 150 ° y tiene correas de velcro ubicadas en la plataforma que aseguran el pie. El diseño de este dispositivo se modeló utilizando un software CAD. Como sistema de medición, se usa un goniómetro en la parte lateral del dispositivo y se utilizan celdas de carga para medir la fuerza con el fin de determinar el torque resistente ejercido por el músculo. La sensibilidad de las celdas de carga es 1.8 ± 0.002 y tienen una repetibilidad de 0.03. La validación de la efectividad del dispositivo se mide al reducir | |
| dc.description.abstractenglish | Spasticity in the plantar flexors muscles as a product of stroke (CVA-Cerebrovascular accident) restricts the mobility and independence of the affected people. Commonly, physiotherapists oversee manually performing the rehabilitation therapy known as Sustained Mechanical Stretching, rotating the affected foot of the patient in the sagittal plane. However, this causes a physical wear on the professional because it is a fatiguing movement. In this article, a Mechanical Device is developed to implement this rehabilitation therapy more efficiently. The device consists of a worm-crown mechanism that is driven by a crank to gradually rotate a platform in the sagittal plane of the affected foot, to achieve dorsiflexion. The device has a range of sagittal rotation up to 150° and has Velcro located on the footplate that secure the foot. The design of this device was modeled by using a CAD. As a measurement system, a goniometer is used in the lateral part of the device and load cells are used to measure the force to determine the opposing torque exerted by the muscle. Load cells sensitivity is 1.8 ± 0.002 and has a repeatability of 0.03. Validation of the effectiveness of the device is | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Mecánico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/39154 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Mecánica | |
| dc.publisher.school | Escuela de Ingeniería Mecánica | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Biomecánica | |
| dc.subject | Dispositivo Mecánico | |
| dc.subject | Estiramiento Mecánico Sostenido | |
| dc.subject | Hemiplejía Espástica | |
| dc.subject | Músculos Plantiflexores | |
| dc.subject.keyword | Biomechanics | |
| dc.subject.keyword | Mechanical Device | |
| dc.subject.keyword | Plantar Flexors Muscles | |
| dc.subject.keyword | Rehabilitation | |
| dc.subject.keyword | Spastic Hemiplegia | |
| dc.subject.keyword | Sustained Mechanical | |
| dc.title | Design and construction of a device that facilitates the stretching of plantar flexors muscles in the therapy of rehabilitation for patients with spastic hemiplegia | |
| dc.title.english | Design and construction of a device that facilitates the stretching of plantar flexors muscles in the therapy of rehabilitation for patients with spastic hemiplegia. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |