Publicación: Diseño de un opamp con bajo voltaje de alimentación para sistemas de detección de señales biomédicas
| dc.contributor.advisor | Mateus Ardila, Juan Carlos | |
| dc.contributor.advisor | Barrero Pérez, Jaime Guillermo | |
| dc.contributor.author | Gómez Caicedo, Jhon Alexander | |
| dc.date.accessioned | 2024-03-03T19:26:58Z | |
| dc.date.available | 2012 | |
| dc.date.available | 2024-03-03T19:26:58Z | |
| dc.date.created | 2012 | |
| dc.date.issued | 2012 | |
| dc.description.abstract | El uso de los sistemas Holter se ha generalizado ya que se utilizan no solo en el campo médico para detectar y prevenir enfermedades, sino también en otros campos, como el deportivo donde son utilizados para el seguimiento y control de la intensidad de actividades de deportistas y atletas. Esto debido a que permiten obtener el ECG de una persona mientras realiza sus actividades diarias. Sin embargo su uso está restringido por el corto tiempo de carga de la batería. Por cuanto se hace necesario presentar una alternativa que contrarreste dicha dificultad, razón por la cual este trabajo busca reducir el voltaje de alimentación del sistema por medio del diseño de un amplificador de biopotencial. Este trabajo presenta el diseño de un amplificador de biopotencial, en un proceso de 90 nm. Se seleccionó la estructura más adecuada para la aplicación de acuerdo a una figura de mérito diseñada específicamente para este proyecto. Posteriormente se realizaron modificaciones en la estructura, principalmente dirigidas a mejorar la estabilidad del sistema, para la cual se implementó una compensación indirecta. Después se realizaron todos los análisis matemáticos que permitieron conocer cualitativamente las características de la estructura y por último se realizó una selección del modelo a utilizar para el diseño de los ransistores, encontrando que el ACM es el óptimo por su exactitud y facilidad para realizar cálculos manuales. Como resultado del diseño, se obtiene un amplificador que trabaja con 0,5 V y cumple con odos los requisitos para la detección de señales bioeléctricas, como una ganancia de 76 dB y un ruido menor a 10 nv/ vVHz. El diseño del circuito se comprueba mediante un análisis de Montecarlo el cual arroja resultados favorables, validando el diseño y corroborando la robustez del diseño ante variaciones en los parámetros. | |
| dc.description.abstractenglish | The use of Holter systems has increased due for detecting and preventing some diseases in the medical field. They are also used ivities. Holter systems are commonly used because they let only used for moni the acquisition of ECG signal fr is restric an altern through This The mos specifical order to sation. After that, there were done different ma’ oring some athlet’s ac ed by the duration of work introduces the c ative that solves this issue. The present he design of a Biopotential OpAmp. om people while he battery charge esign of a Biopo improve system stabi ity which was ac o its utility in diverse areas. They are not oing their daily activities. However, its use . For this reason its necessary to introduce project looks for decreasing system voltage ential OpAmp using a 90nm technology. suitable structure for the selected application was chosen using a figure of merit y designed for this project. Then, modifications to the structure were done in 1ieved implementing an indirect compen- hematical analisys for knowing the main cualitative characteristics of the structure used. Finally, the ACM transistor model was selected for the design, considering its accurancy and easiness when doing manual calculations. As result from the design, it was obtained an amplifier that works with 0,5 V and satisfies all the bioelectrical signal detection requirements, like a 76 dB gain and noise lower than 10 nv /VHz. The design was proved with Montecarlo analisys wich gives fair results, validating the circuit and bearing out the sturdiness of the design against its parameters variation. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/26526 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | OpAmp | |
| dc.subject | Bajo voltaje | |
| dc.subject | Sub-umbral. | |
| dc.subject.keyword | OpAnp | |
| dc.subject.keyword | Low voltage | |
| dc.subject.keyword | Sub-theshold. | |
| dc.title | Diseño de un opamp con bajo voltaje de alimentación para sistemas de detección de señales biomédicas | |
| dc.title.english | Abstract design of a low-voltage opamp for biomedical signal detection systems? | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 397.83 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 398.17 KB
- Formato:
- Adobe Portable Document Format