Publicación: Evaluación del comportamiento extructural al modificar la altura del pilono en un puente extradosado de luz central igual 100 m
| dc.contributor.advisor | Chio Cho, Gustavo | |
| dc.contributor.advisor | Benjumea Royero, Jose Miguel | |
| dc.contributor.author | Peña Barrera, Jhon Alexander | |
| dc.contributor.author | Vargas Arevalo, Andres Leonardo | |
| dc.date.accessioned | 2024-03-03T18:36:55Z | |
| dc.date.available | 2011 | |
| dc.date.available | 2024-03-03T18:36:55Z | |
| dc.date.created | 2011 | |
| dc.date.issued | 2011 | |
| dc.description.abstract | Los puentes extradosados son un tema de actualidad en el ámbito de la ingeniería de puentes a nivel mundial que han emergido como una nueva opción para puentes de luces medias. Mediante la utilización del hormigón y la tecnología del pretensado, se busca, en asociación con los tendones de acero como tirantes, plantear una solución marcadamente favorable hacia estas estructuras. La idea introducida por Mathivat en 1988, presenta una tipología estructural semejante a los puentes de tirantes pero con pilonos de menor altura y mayores cantos. En este estudio se ha analizado el comportamiento estructural de un puente extradosado de luz central igual a 100 metros al modificar la altura del pilono. Esta tipología de puente ha despertado el interés de su implementación en Colombia, por ello en esta investigación se evaluó su comportamiento bajo el estado límite de serviciosegún el Código Colombiano de Diseño Sísmico de Puentes, en la cual se determinó y cuantifico en qué medida la altura del pilono influye y condiciona el comportamiento del puente con pretensado extradosado, tipología que busca que la variación de tensión en el acero de los tendones extradosados, debida a la sobrecarga, sea lo suficientemente baja evitando los problemas de fatiga asociados a los anclajes y tendones existentes en un puente extradosado.Se realizó un análisis paramétrico donde se compararon las características más relevantes en el comportamiento estructural logrando concluir un rango en la altura óptima de pilono, la cual garantiza un mejor comportamiento estructural de los cables, y que es a la vez el rango de mayor uso en los puentes extradosados construidos hasta la fecha. | |
| dc.description.abstractenglish | Extradosed bridges are actually topic in the field bridges engineering in the worldwide that have emerged as a new option for medium span bridges. Using the technology of concrete and prestressed, we seek, in association with steel tendons and strained, markedly raise a favorable solution to these structures. the idea introduced by mathivat in 1988, presents a structural typology like braces bridges but with lower height pylons and greater heights of boards. In this study we have analyzed the structural performance a central span extradosedbridge just 100 meters change the height of the pylon. this type of bridge has attracted the interest of its implementation in Colombia, so therefore evaluated in this study their behavior under service limit state according to the Colombian Code Seismic Design of Bridges, in which it identifies and quantifies the extent of the pylon height influences and determines the behavior of prestressed bridge extradosed, typology for the variation of tension in the steel tendons extradosed due to overload, is low enough to avoid fatigue problems associated with existing anchors and tendons on a bridge extradosed. Parametric analysis was performed which compared the most relevant features in the structural behavior completing a range in the optimum height of pylon, which guarantees a better structural behavior of the cables, and that is at once the most widely used range extradosed bridges built to date. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Civil | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/25011 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Civil | |
| dc.publisher.school | Escuela de Ingeniería Civil | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Puente | |
| dc.subject | extradosado | |
| dc.subject | Pilono | |
| dc.subject | Variación de tensión | |
| dc.subject | Fatiga | |
| dc.subject | Anclajes. | |
| dc.subject.keyword | extradosed | |
| dc.subject.keyword | Pylon | |
| dc.subject.keyword | Variation tension | |
| dc.subject.keyword | Fatigue | |
| dc.subject.keyword | Anchors | |
| dc.title | Evaluación del comportamiento extructural al modificar la altura del pilono en un puente extradosado de luz central igual 100 m | |
| dc.title.english | Structural behavior evaluation to modify the height of pylon in an extradosed bridges of a central span equal to 100 meters. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |