Publicación: Analisis sismico de tanques elevados de agua sobre diferentes sistemas estructurales de hormigon reforzado en la ciudad de bucaramanga
| dc.contributor.advisor | Chio Cho, Gustavo | |
| dc.contributor.author | Mantinez Galindo, Eduardo Antonio | |
| dc.contributor.author | Sanchez Arregui, Leonardo Fabian | |
| dc.date.accessioned | 2024-03-03T04:42:58Z | |
| dc.date.available | 2004 | |
| dc.date.available | 2024-03-03T04:42:58Z | |
| dc.date.created | 2004 | |
| dc.date.issued | 2004 | |
| dc.description.abstract | En nuestro país, el análisis de tanques elevados de agua en edificaciones, se realiza de una forma demasiado simple que no toma en cuenta las características hidrodinámicas que un sismo induce en el agua almacenada, esas características son fundamentalmente una consecuencia del movimiento del liquido en su superficie libre, fenómeno que se conoce con el nombre de SLOSHING. Para llevar a cabo un análisis mucho más real de las estructuras existe un modelo que fue propuesto por G.W Housner en el año de 1963, en el cual los efectos hidrodinámicos del agua se incluyen en el análisis con una masa que oscila dentro del tanque, llamada masa convectiva la cual se une a la estructura por medio de unos elementos que simulan el comportamiento de un resorte. Para llevar a cabo el análisis de las estructuras fue necesaria, la integración del modelo propuesto por Housner con el modelo de la estructura, para esto se utilizó el software SAP-2000, del cual se obtuvieron las respuestas que posteriormente fueron analizadas. Las repuestas de las estructuras cuando tienen en su configuración los tanques elevados, hacen creer que el pensamiento que se tiene por parte de la mayoría de los Ingenieros que es una masa oscilando libremente en la parte superior de la estructura es perjudicial para esta es equivocada porque en muchas de las respuestas estudiadas el tanque actuó como un | |
| dc.description.abstractenglish | In our country, the analysis of high tanks of water in constructions, is carried out in a too simple way that doesn't take into account the hydrodynamic characteristics that an earthquake induces in the stored water, those characteristics they are fundamentally a consequence of the movement of the I liquidate in its free surface, phenomenon that is known with the name of SLOSHING. To carry out a much realler analysis of the structures a model that was proposed by G.W Housner in the year of 1963, in which the hydrodynamic effects of the water are included in the analysis with a mass that oscillates inside the tank, called convective mass which unites to the structure by means of some elements that simulate the behavior of a spring exists. To carry out the analysis of the structures it was necessary, the integration of the pattern proposed by Housner with the pattern of the structure, for this the software be used SAP-2000, of which the answers were obtained that later on were analyzed. Those restored of the structures when they have in their configuration the high tanks, they make believe that the thought that one has on the part of most of the Engineers that it is "a mass oscillating freely in the superior part of the structure is harmful for this" it is mistaken because in many of the studied answers the tank acted as a | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Civil | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/16834 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Civil | |
| dc.publisher.school | Escuela de Ingeniería Civil | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Tanques Elevados | |
| dc.subject | Características Hidrodinámicas | |
| dc.subject | Sloshing | |
| dc.subject | Masa Conectiva | |
| dc.subject | Modelo De Housner | |
| dc.subject.keyword | Elevated | |
| dc.subject.keyword | Tanks Hydrodynamic | |
| dc.subject.keyword | Characteristic Sloshing Convective | |
| dc.subject.keyword | Mass Housner | |
| dc.subject.keyword | Model Dissipator | |
| dc.title | Analisis sismico de tanques elevados de agua sobre diferentes sistemas estructurales de hormigon reforzado en la ciudad de bucaramanga | |
| dc.title.english | Seismic analysis of elevated water tanks on differents structural systems of reinforced concrete in the city of bucaramanga. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |