Publicación: Montaje, operación y calibración de la estación hidrométrica automática para medición de niveles en el Rio de Oro, estación conquistador alto
| dc.contributor.advisor | Guzman Jaimes, Jorge Alberto | |
| dc.contributor.author | Hernández, Laura Isabel | |
| dc.contributor.author | Saltarin Mesa, Diego Andres | |
| dc.date.accessioned | 2024-03-03T16:39:57Z | |
| dc.date.available | 2007 | |
| dc.date.available | 2024-03-03T16:39:57Z | |
| dc.date.created | 2007 | |
| dc.date.issued | 2007 | |
| dc.description.abstract | El actual estado de abandono de las estaciones de monitoreo hidrológico en Colombia, no permite realizar avances en el estudio de sus ríos, debido a la información imprecisa y al gran porcentaje de error generado por las mediciones manuales. Pensando en estos factores, se crea el convenio entre la Empresa Piedecuestana de Servicios y el Grupo de Predicción Hidroclimática GPH de la universidad industrial de Santander, con el cual se realiza el montaje de una Estación Hidrométrica Automática en la parte Alta del Río de Oro, denominada Estación Conquistador Altofl. Durante la realización de esta segunda fase del proyecto, se evaluó la implementación de este sistema de registro automatizado, dando inicio como tal a la operación de los equipos instalados. Estos dispositivos de registro son el Diver y el Barodiver, los cuales están ubicados dentro un tubo de acero inoxidable, que provee el medio necesario para las mediciones, permitiendo registros de series de tiempo de niveles y temperatura a una alta resolución temporal, utilizando tecnología de Schlumberger Water Services y Van Essen Instruments BV. Además de la automatización de las mediciones manuales, para la realización de los aforos se utilizo tecnología de punta con un medidor de flujo acústico portátil (ADV Flowtracker) de Sontek, el cual permite registros de caudales con un porcentaje mínimo de error. Como estudios complementarios, se realizo el modelamiento del tramo del río que cobija la estación, estudiando la influencia por represamiento de la estructura hidráulica reguladora de aguas abajo, en los registros obtenidos | |
| dc.description.abstractenglish | The current condition of abandonment of hydrologic monitoring stations in Colombia, does not allow carrying out advances in the study of its rivers, due to imprecise information and to the great error percentage generated by manual mensurations. Thinking of these factors, an agreement between Piedecuestana de servicios and the hydroclimatic prediction group GPH of the Universidad industrial de Santander was created, with which the assembly of an automatic hydrometric station in the high part of the Rio de Oro is carried out, denominated Estación Conquistador Altofl. During the realization of this second phase of the project, the implementation of this system of automated registration was evaluated, beginning the operation of the installed equipment as such. These registration devices are the Diver and the Barodiver, which are located inside a stainless steel tube that provides the necessary means for the mensurations, allowing time series registrations of levels and temperature in a high temporary resolution, using technology of Schlumberger Water Services and Van Essen Instruments BV. In addition to the automation of the manual mensurations, the latest in technology was used to make the gauglings, with a portable acoustic flow tracker (ADV Flowtracker) of Sontek, which allows registrations of flows with a minimum percentage of error. As complementary studies, the modeling of this river's stretch that is covered by the station was made, studying the influence by damming caused by the downstream hydraulic structure, in the registrations | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Civil | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/20356 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Civil | |
| dc.publisher.school | Escuela de Ingeniería Civil | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Estación Hidrométrica Automática | |
| dc.subject | Diver | |
| dc.subject | Barodiver | |
| dc.subject | ADV Flowtracker | |
| dc.subject | Modelamiento. | |
| dc.subject.keyword | Automatic Hydrometric Station | |
| dc.subject.keyword | Diver | |
| dc.subject.keyword | Barodiver | |
| dc.subject.keyword | ADV Flowtracker | |
| dc.subject.keyword | Modeling. | |
| dc.title | Montaje, operación y calibración de la estación hidrométrica automática para medición de niveles en el Rio de Oro, estación conquistador alto | |
| dc.title.english | Installation, operation and calibration of an automaty hidrometric station for measurements of levels on rio de oro, conquistador alto station. * | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |