Publicación: Diseño de un implante ajustado a la geometría ósea del cráneo, caso de estudio. Pasantía de investigación
| dc.contributor.advisor | López Gualdron, Clara Isabel | |
| dc.contributor.advisor | Galeano Arrieta, Carlos Fernando | |
| dc.contributor.author | González Carvajal, Maria Jose | |
| dc.date.accessioned | 2024-03-03T22:12:53Z | |
| dc.date.available | 2015 | |
| dc.date.available | 2024-03-03T22:12:53Z | |
| dc.date.created | 2015 | |
| dc.date.issued | 2015 | |
| dc.description.abstract | El objetivo del presente trabajo de investigación es a partir de la revisión de literatura, analizar los contenidos sobre los consensos y soluciones, de implantes a la medida para diferentes casos de estudio, que presentan defectos óseos en el cráneo. En los resultados principales se establecieron los consensos identificados, en las diferentes estructuras metodológicas y soluciones de diseño de implantes a la medida, propuestas por los autores en sus artículos de investigación, sobre compromiso de trauma craneal óseo. Con base en el análisis de lo existente, la revisión de literatura y la opinión de los expertos, se definieron las metodologías y protocolos, los cuales se integraron en el proceso de desarrollo de nuevos productos para el sector ortopédico, específicamente implantes ajustados a la geometría ósea craneal, para casos que requieran ser intervenidos por craneoplastia. Este desarrollo tuvo un proceso multidisciplinar, en el que participaron diseño, cirugía y manufactura, integrando el equipo de co-creación. De igual forma, como componente importante del presente trabajo de investigación, se resaltará la incidencia, de la integración del proceso de pre planeación quirúrgica, así como de tecnologías Bio-CAD, CAD, CAE, RP y herramientas software para el desarrollo de este tipo de implantes. El resultado obtenido fueron tres alternativas de diseño de implantes ajustados a la geometría ósea de cráneo, las cuales fueron sometidas a evaluación por parte de los expertos y cuyas valoraciones fueron fundamentales para diseñar una cuarta y final alternativa, que cumple con los requerimientos establecidos y además con las sugerencias registradas en los formatos de evaluación realizada a los expertos. . | |
| dc.description.abstractenglish | The objective of this research is based on literature review, analyze the contents of the consensus and solutions of implants for different case studies that presented skull bone defects. In the main findings identified consensus on the different methodological and design solutions of custom implants, proposed by the authors in their research papers on cranial trauma commitment bone structures were established. Based on the analysis of the existing literature review and expert opinion, methodologies and protocols were defined, which were integrated into the process of developing new products for the orthopedic sector, specifically adjusted geometry implants cranial bone, for cases that require surgery for cranioplasty. This development had a multidisciplinary process, involving design, surgery and manufacturing, integrating the team of co-creation. Similarly, as an important component of this research, the impact of the integration of the pre surgical planning, as well as Bio-CAD, CAD, CAE, RP technologies and software tools for the development of this type will be highlighted implant. The result was three design alternatives implants adjusted to bone geometry skull, which were subjected to evaluation by experts and whose valuations were instrumental in designing fourth and final alternative that meets the requirements established and well registered with suggestions assessment formats experts. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Diseñador Industrial | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/33199 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Diseño Industrial | |
| dc.publisher.school | Escuela de Diseño Industrial | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Implantes A La Medida | |
| dc.subject | Diseño | |
| dc.subject | Bio-Cad | |
| dc.subject | Co-Creación | |
| dc.subject | Revisión De Literatura | |
| dc.subject.keyword | Custom Implants | |
| dc.subject.keyword | Design | |
| dc.subject.keyword | Bio-Cad | |
| dc.subject.keyword | Co-Creation | |
| dc.subject.keyword | Literature Review. | |
| dc.title | Diseño de un implante ajustado a la geometría ósea del cráneo, caso de estudio. Pasantía de investigación | |
| dc.title.english | Design of an implant adjusted skull bone geometry, case study. research internship | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 225.42 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 199.99 KB
- Formato:
- Adobe Portable Document Format
