Publicación: Determinación de parámetros de modelos para el estudio del comportamiento de cargas lumínicas del edificio de ingeniería eléctrica ante variaciones de la amplitud y frecuencia de la tensión de alimentación
| dc.contributor.advisor | Osma Pinto, German Alfonso | |
| dc.contributor.advisor | Malagon Carvajal, Gabriel Alexis | |
| dc.contributor.advisor | Florez Reyes, Julian Oswaldo | |
| dc.contributor.author | Carrillo Sandoval, Luisa Fernanda | |
| dc.contributor.author | Martinez Peñaloza, Alejandra | |
| dc.date.accessioned | 2024-03-04T00:05:03Z | |
| dc.date.available | 2018 | |
| dc.date.available | 2024-03-04T00:05:03Z | |
| dc.date.created | 2018 | |
| dc.date.issued | 2018 | |
| dc.description.abstract | El Edificio de Ingeniería Eléctrica de la Universidad Industrial de Santander, comprometido con el medio ambiente, es un ejemplo piloto de edificación verde. Una de sus aplicaciones sostenibles es un sistema de generación fotovoltaica (SFV) conectado a la red de baja tensión. Estos sistemas de generación utilizan elementos basados en la electrónica de potencia, microinversores, capaces de producir distorsión en la forma de onda de la señal de tensión y corriente, afectando la calidad de la potencia en la red eléctrica. Por tanto, es de gran importancia conocer cuáles son los comportamientos de las cargas cuando son alimentadas con este tipo de sistema de generación. En este sentido, el objetivo principal de este trabajo de investigación, fue el estudio del comportamiento de las cargas lumínicas del Edificio de Ingeniería Eléctrica ante diversos escenarios de tensión distorsionada. El presente trabajo, presenta inicialmente una revisión de las bases técnicas de los modelos de cagas y herramientas matemáticas y computacionales utilizadas para el cálculo de los parámetros de los modelos y la potencia consumida. Posteriormente, se presenta el proceso de la experimentación del registro de muestras de la forma de onda de la señal eléctrica producida por las cargas en estudio, teniendo en cuenta los equipos y cargas utilizadas. Seguidamente se realiza la descripción de la programación desarrollada en MATLAB para el cálculo de los parámetros de los modelos estudiados, realizando luego un análisis de los resultados obtenidos en el programa, eligiendo el modelo que mejor describa el comportamiento de las luminarias acorde con los valores medidos. Por último, se realiza un estudio de cuantificación de las variaciones de potencia activa y potencia reactiva para cada caso de estudio provisto para las luminarias y sus modos de operación con señales de tensión de alimentación distorsionadas. | |
| dc.description.abstractenglish | The Electrical Engineering Building of the Industrial University of Santander, committed to the environment, is a pilot example of green building. One of its sustainable applications is a photovoltaic generation system (PGS) connected to the low voltage network. These generation systems use elements based on power electronics, microinverters, capable of producing distortion in the waveform of the voltage and current signal, affecting the quality of power in the electrical network. Therefore, it is very important to know what the behaviors of the loads are when they are fed with this type of generation system. In this sense, the main objective of this research work was the study of the behavior of the light loads of the Electrical Engineering Building in different scenarios of distorted voltage. The present work, presents initially a revision of the technical bases of the models of loads and mathematical and computational tools used for the calculation of the parameters of the models and the power consumed. Subsequently, the process of experimenting with the recording of samples of the waveform of the electrical signal produced by the charges under study is presented, taking into account the equipment and loads used. Then the description of the programming developed in MATLAB for the calculation of the parameters of the models studied is made, later making an analysis of the results obtained in the program, choosing the model that best describes the behavior of the luminaries according to the measured values. Finally, a quantification study of the variations of active power and reactive power is carried out for each case of study provided for the luminaires and their modes of operation with distorted supply voltage signals. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electricista | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/38634 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Eléctrica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Modelo En El Dominio De La Frecuencia | |
| dc.subject | Modelo Zip | |
| dc.subject | Modelo Exponencial | |
| dc.subject | Barrido Armónico | |
| dc.subject | Luminarias On/Off Y Dimerizable Y Matriz De Admitancia Acoplada. | |
| dc.subject.keyword | Frequency Domain Modeling | |
| dc.subject.keyword | Zip Model | |
| dc.subject.keyword | Exponential Model | |
| dc.subject.keyword | Harmonic Sweep | |
| dc.subject.keyword | Coupled Admittance Matrix And Light Loads. | |
| dc.title | Determinación de parámetros de modelos para el estudio del comportamiento de cargas lumínicas del edificio de ingeniería eléctrica ante variaciones de la amplitud y frecuencia de la tensión de alimentación | |
| dc.title.english | De termination of model parameters for the study of the behavior of the light loads of the electrical engineering building before variations in the amplitude and frequency of the supply voltage* | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 338.55 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Documento.pdf
- Tamaño:
- 12.03 MB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 238.3 KB
- Formato:
- Adobe Portable Document Format