Determinación de parámetros de modelos para el estudio del comportamiento de cargas lumínicas del edificio de ingeniería eléctrica ante variaciones de la amplitud y frecuencia de la tensión de alimentación

dc.contributor.advisorOsma Pinto, German Alfonso
dc.contributor.advisorMalagon Carvajal, Gabriel Alexis
dc.contributor.advisorFlorez Reyes, Julian Oswaldo
dc.contributor.authorCarrillo Sandoval, Luisa Fernanda
dc.contributor.authorMartinez Peñaloza, Alejandra
dc.date.accessioned2024-03-04T00:05:03Z
dc.date.available2018
dc.date.available2024-03-04T00:05:03Z
dc.date.created2018
dc.date.issued2018
dc.description.abstractEl Edificio de Ingeniería Eléctrica de la Universidad Industrial de Santander, comprometido con el medio ambiente, es un ejemplo piloto de edificación verde. Una de sus aplicaciones sostenibles es un sistema de generación fotovoltaica (SFV) conectado a la red de baja tensión. Estos sistemas de generación utilizan elementos basados en la electrónica de potencia, microinversores, capaces de producir distorsión en la forma de onda de la señal de tensión y corriente, afectando la calidad de la potencia en la red eléctrica. Por tanto, es de gran importancia conocer cuáles son los comportamientos de las cargas cuando son alimentadas con este tipo de sistema de generación. En este sentido, el objetivo principal de este trabajo de investigación, fue el estudio del comportamiento de las cargas lumínicas del Edificio de Ingeniería Eléctrica ante diversos escenarios de tensión distorsionada. El presente trabajo, presenta inicialmente una revisión de las bases técnicas de los modelos de cagas y herramientas matemáticas y computacionales utilizadas para el cálculo de los parámetros de los modelos y la potencia consumida. Posteriormente, se presenta el proceso de la experimentación del registro de muestras de la forma de onda de la señal eléctrica producida por las cargas en estudio, teniendo en cuenta los equipos y cargas utilizadas. Seguidamente se realiza la descripción de la programación desarrollada en MATLAB para el cálculo de los parámetros de los modelos estudiados, realizando luego un análisis de los resultados obtenidos en el programa, eligiendo el modelo que mejor describa el comportamiento de las luminarias acorde con los valores medidos. Por último, se realiza un estudio de cuantificación de las variaciones de potencia activa y potencia reactiva para cada caso de estudio provisto para las luminarias y sus modos de operación con señales de tensión de alimentación distorsionadas.
dc.description.abstractenglishThe Electrical Engineering Building of the Industrial University of Santander, committed to the environment, is a pilot example of green building. One of its sustainable applications is a photovoltaic generation system (PGS) connected to the low voltage network. These generation systems use elements based on power electronics, microinverters, capable of producing distortion in the waveform of the voltage and current signal, affecting the quality of power in the electrical network. Therefore, it is very important to know what the behaviors of the loads are when they are fed with this type of generation system. In this sense, the main objective of this research work was the study of the behavior of the light loads of the Electrical Engineering Building in different scenarios of distorted voltage. The present work, presents initially a revision of the technical bases of the models of loads and mathematical and computational tools used for the calculation of the parameters of the models and the power consumed. Subsequently, the process of experimenting with the recording of samples of the waveform of the electrical signal produced by the charges under study is presented, taking into account the equipment and loads used. Then the description of the programming developed in MATLAB for the calculation of the parameters of the models studied is made, later making an analysis of the results obtained in the program, choosing the model that best describes the behavior of the luminaries according to the measured values. Finally, a quantification study of the variations of active power and reactive power is carried out for each case of study provided for the luminaires and their modes of operation with distorted supply voltage signals.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Electricista
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/38634
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programIngeniería Eléctrica
dc.publisher.schoolEscuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectModelo En El Dominio De La Frecuencia
dc.subjectModelo Zip
dc.subjectModelo Exponencial
dc.subjectBarrido Armónico
dc.subjectLuminarias On/Off Y Dimerizable Y Matriz De Admitancia Acoplada.
dc.subject.keywordFrequency Domain Modeling
dc.subject.keywordZip Model
dc.subject.keywordExponential Model
dc.subject.keywordHarmonic Sweep
dc.subject.keywordCoupled Admittance Matrix And Light Loads.
dc.titleDeterminación de parámetros de modelos para el estudio del comportamiento de cargas lumínicas del edificio de ingeniería eléctrica ante variaciones de la amplitud y frecuencia de la tensión de alimentación
dc.title.englishDe termination of model parameters for the study of the behavior of the light loads of the electrical engineering building before variations in the amplitude and frequency of the supply voltage*
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
338.55 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
12.03 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
238.3 KB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031