Publicación: Evaluación experimental de un tlcd en un modelo a escala
| dc.contributor.advisor | Cruz Hernández, Ricardo Alfredo | |
| dc.contributor.advisor | Begambre Carrillo, Oscar Javier | |
| dc.contributor.author | Chaparro Tarazona, Andrés Carolina | |
| dc.contributor.author | Santamaria Ariza, Mónica Patricia | |
| dc.date.accessioned | 2024-03-03T19:32:45Z | |
| dc.date.available | 2012 | |
| dc.date.available | 2024-03-03T19:32:45Z | |
| dc.date.created | 2012 | |
| dc.date.issued | 2012 | |
| dc.description.abstract | Debido al crecimiento en el uso de materiales de alta resistencia y a las técnicas de construcción modernas, edificios y otras estructuras se construyen de gran esbeltez y por tanto son más flexibles y poseen bajo amortiguamiento. Las vibraciones causadas por vientos y sismos que han sido de gran interés para los ingenieros civiles, son en consecuencia más severas para este tipo de estructuras esbeltas que para edificaciones de baja altura, lo cual lleva a un incremento en la incomodidad de los ocupantes, y daños en elementos estructurales y no estructurales. En la actualidad se ha venido incrementando el uso de sistemas de control estructural con el fin de mantener la respuesta de estas edificaciones bajo unos límites de seguridad para la edificación y reducir a un mínimo el riesgo de pérdida de vidas humanas. Los disipadores de columna líquida sintonizada (TLCD) hacen parte de los sistemas de control existentes y son relativamente fáciles de instalar en edificios nuevos o existentes ya que no requieren de una fuente de alimentación externa para su funcionamiento. Este proyecto tiene como finalidad evaluar de manera experimental el comportamiento dinámico de una estructura metálica de dos pisos con un sistema de control pasivo de columna líquida sintonizada, frente a una excitación en la base producida por una mesa sísmica de un grado de libertad. La respuesta se compara con la de un modelo de iguales características sin TLCD, evaluando la disipación de energía alcanzada con la implementación del dispositivo de control pasivo, mediante la comparación de la respuesta dinámica que comprende aceleraciones, velocidades y desplazamientos. | |
| dc.description.abstractenglish | Because of the growing use of high-strength materials and modern construction techniques, buildings and other structures are built very slender and therefore they are more flexible and have low damping. The vibrations caused by winds and earthquakes that have been of great interest for civil engineers, are in consequence more severe for such slender structures than for low-rise buildings, which leads to an increase in the discomfort of the occupants, and structural and non-structural damage of elements. Nowadays, there has been an increase in the use of structural control systems in order to maintain the response of these buildings under safe limits for the building and minimize the risk of human life losses. The tuned liquid column dampers (TLCD) are part of the existing structural systems and are relatively easy to install in new buildings or existing ones, as they do not require external power for operation. This project aims to evaluate experimentally the dynamic behavior of a two-story steel structure with a passive structural control of tuned liquid column damper, subjected to a base excitation produced by a shaking table of one degree of freedom. The response is compared to a model with the same characteristics without the TLCD, evaluating the energy dissipation achieved with the implementation of the passive control device, by comparing the dynamic response through acceleration, velocity and displacement. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Civil | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/27131 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Civil | |
| dc.publisher.school | Escuela de Ingeniería Civil | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Sistemas de control | |
| dc.subject | Respuesta dinámica | |
| dc.subject | Disipadores de columna líquida sintonizada | |
| dc.subject | Control de vibraciones. | |
| dc.subject.keyword | Structural Control | |
| dc.subject.keyword | Dynamic Behavior | |
| dc.subject.keyword | Tuned liquid column dampers | |
| dc.subject.keyword | Vibration control. | |
| dc.title | Evaluación experimental de un tlcd en un modelo a escala | |
| dc.title.english | Experimental evaluation of a tlcd on a scale model | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |