Obtención experimental de funciones de transferencia que relacionan la fuerza aplicada en los movimientos básicos de la mano con la actividad electromiografica del antebrazo

dc.contributor.advisorVillamizar Mejia, Rodolfo
dc.contributor.advisorSandoval, Camilo Leonardo
dc.contributor.authorPérez Gamboa, Oscar Eduardo
dc.contributor.authorAmado Duarte, Laura Yazmin
dc.date.accessioned2024-03-03T18:05:04Z
dc.date.available2010
dc.date.available2024-03-03T18:05:04Z
dc.date.created2010
dc.date.issued2010
dc.description.abstractEn este artículo es presentado el desarrollo de un experimento para identificar el sistema EMG-Fuerza muscular durante los movimientos básicos de la mano (flexión-extensión, abducción-aducción y pronación-supinación). La obtención de modelos que relacionen tanto EMG como fuerza permite mejorar el control de prótesis, perfeccionando su funcionalidad y naturalidad. Por ello el presente proyecto buscó obtener experimentalmente una función de trasferencia para cada movimiento a partir de las señales registradas de fuerza y EMG. Finalmente se evaluó la variación paramétrica para cada función bajo diferentes condiciones de trabajo. La ejecución del proyecto se realizó mediante la siguiente metodología: primero se diseñó la instrumentación para la medición de la fuerza, la cual fue adquirida mediante el software Labview con una tarjeta de adquisición de datos NI (National Instruments). A su vez la señal EMG fue registrada con un electromiógrafo. Posteriormente las señales obtenidas fueron procesadas para realizar la identificación del sistema EMG-Fuerza y su respectiva verificación con Labview. Como resultado de la implementación de la metodología propuesta se destacó la obtención del error medio cuadrático a partir de la verificación del modelo para cada movimiento, para el cual el movimiento de supinación arrojó el menor error (0.0001%) y el de pronación el mayor (4.6428%). Así mismo con base a la identificación del sistema fue obtenida una función de transferencia de segundo orden, la cual fue validada demostrando que efectivamente la relación EMGFuerza es un sistema de orden dos. Finalmente se realizó un análisis estadístico para la variación paramétrica de las funciones con respecto a la carga y al paciente, del cual se observó que los parámetros del modelo para cada movimiento seguían la media. Por tanto se concluyo que para cada movimiento de la mano la función de transferencia es generalizada de orden dos, independientemente del paciente o las condiciones de trabajo.
dc.description.abstractenglishThe development of an experiment to identify the EMG-Muscular force during basic hand movements (flexion-extension, abduction-aduction and pronation-supination) is presented on this article. Obtaining models that relate EMG with force can be used to improve prosthesis control by perfecting its functionality and nature. Because of this, the present project sought to obtain, experimentally, a transfer function for each movement based on some force and EMG signals previously acquired. Finally, the parametric variation of each function was evaluated for some operation conditions. The Project was done using this methodology: First, force measurement hardware was designed, and the force itself was acquired using LabView with a National Instruments Data acquisition card. Alongside, The EMG signal was registered using an electromyograph. Then the obtained signals were processed to identify the EMG-force system and it was verified with LabView. Mean quadratic error was obtained through model verification for each movement. Supination had the lowest error (0.0001%) and pronation had the highest (4.6428%). Through system identification a second order transfer function was obtained and validated. Finally a statistic analysis for parametric variation, using the load and the patient, of each function was implemented, obtaining a behavior close to the predicted mean. Thus, every hand movement and its EMG-force relation could be modeled with a second order transfer function, regardless of the patient or working conditions.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Electrónico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/23356
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programIngeniería Electrónica
dc.publisher.schoolEscuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectElectromiografía (EMG)
dc.subjectEstimación de la fuerza
dc.subjectIdentificación de sistemas y Prótesis de antebrazo.
dc.subject.keywordElectromyography (EMG)
dc.subject.keywordForce estimation
dc.subject.keywordSystem identification
dc.subject.keywordForearm prosthesis.
dc.titleObtención experimental de funciones de transferencia que relacionan la fuerza aplicada en los movimientos básicos de la mano con la actividad electromiografica del antebrazo
dc.title.englishExperimental acquisition of tranfer functions relating applied force in basic hand movements with _ the forearm electromyographic activity?
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
1.72 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
8.92 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
1.16 MB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031