Publicación: Diseño de una fuente de corriente senoidal y de pulsos bifásicos para medición de espectro de impedancia eléctrica en tejido humano
| dc.contributor.advisor | Barrero Perez, Jaime Guillermo | |
| dc.contributor.advisor | Miranda Mercado, David Alejandro | |
| dc.contributor.author | Cubides Diaz, Yorlen Astrid | |
| dc.contributor.author | Mieles Pinto, Fidel Enrique | |
| dc.date.accessioned | 2024-03-03T16:06:37Z | |
| dc.date.available | 2006 | |
| dc.date.available | 2024-03-03T16:06:37Z | |
| dc.date.created | 2006 | |
| dc.date.issued | 2006 | |
| dc.description.abstract | En el documento se describe el diseño e implementación de una Fuente de Corriente Senoidal y de Pulsos Bifásicos con pantalla LCD alfanumérica para realizar mediciones de espectro de impedancia eléctrica en tejido humano controlada mediante el DSP 56F801 de Motorola. En el primer capítulo se hace una descripción de diferentes topologías de fuentes de corriente; también se presenta información sobre interferencia, ruido, DSP 56F801y seguridad eléctrica. El Hardware implementado en este proyecto está conformado por 3 tarjetas electrónicas: Tarjeta de desarrollo del DSP 56F801 de Motorola, Tarjeta Interfaz y Tarjeta Fuente de Corriente, cuyas etapas de diseño se encuentran explicadas detalladamente en el segundo capítulo. En el tercer capítulo se exponen los algoritmos empleados para la generación y control de las señales senoidal y pulsos, y para el control de la pantalla LCD. En el cuarto capítulo se presentan los resultados de las pruebas realizadas a cada una de las fuentes de corriente, con el fin evaluar el desempeño del dispositivo diseñado. Para esto se verificó en primer lugar, el correcto funcionamiento de la pantalla LCD en conjunto con la tarjeta Fuente de Corrientefl, luego de esto, se llevaron a cabo pruebas empleando el método de medición tensión-corriente con variación de frecuencia y de carga. Los resultados obtenidos permitieron establecer un rango de cargas apropiado para cada tipo de fuente y demostraron la invariabilidad de la corriente con respecto a la frecuencia. Finalmente en el último capítulo se mencionan las conclusiones y recomendaciones. | |
| dc.description.abstractenglish | This document describes the design and implementation of a sinusoidal and dual-phase pulse current source with alpha-numeric LCD to perform measurements of the electrical impedance spectrum in human tissue controlled by the DSP Motorola 56F801. The first chapter describes the different topologies for current sources; and presents some information on interference, noise, the DSP 56F801 and electrical security. The hardware implemented in this project consists of 3 electronic boards: Development Board for the DSP 56F801, Interface Board and the Current Source Board. The design stages are explained in detail on the second chapter. The third chapter shows the algorithms used for the generation and control of the sinusoidal and pulse signals as well as the control algorithm for the LCD display. The fourth chapter presents the results of the tests performed with each of the current sources to evaluate the performance of the equipment. The correct performance of the LCD display was tested along with the Current Source Board, then; several tests were carried out using the voltage-current method with frequency and load variation. The results obtained from these tests allowed to set a load range appropriate for each type of source and demonstrated the invariability of the current with respect to the frequency. The conclusions and recommendations are presented in the fifth and final chapter. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/18376 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Fuente de corriente | |
| dc.subject | Impedancia eléctrica | |
| dc.subject | Frecuencia | |
| dc.subject | Período | |
| dc.subject | DSP | |
| dc.subject | LCD y | |
| dc.subject.keyword | Current Source | |
| dc.subject.keyword | Electrical Impedance | |
| dc.subject.keyword | Frequency | |
| dc.subject.keyword | Period | |
| dc.subject.keyword | DSP | |
| dc.subject.keyword | LCD and PCB. | |
| dc.title | Diseño de una fuente de corriente senoidal y de pulsos bifásicos para medición de espectro de impedancia eléctrica en tejido humano | |
| dc.title.english | Design of a sinusoidal and dual-phase pulse current source for the measurement of the electrical impedance spectrum in human tissue. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |