Mejoramiento de un sistema inteligente de irrigación de paneles fotovoltaicos ubicados sobre techo verde
dc.contributor.advisor | Osma Pinto, German Alfonso | |
dc.contributor.advisor | Ordoñez Plata, Gabriel | |
dc.contributor.advisor | Florez Reyes, Julian Oswaldo | |
dc.contributor.author | Martinez Jimenez, Juan Diego | |
dc.contributor.author | Paez Amador, Gustavo Adolfo | |
dc.date.accessioned | 2024-03-03T23:27:03Z | |
dc.date.available | 2017 | |
dc.date.available | 2024-03-03T23:27:03Z | |
dc.date.created | 2017 | |
dc.date.issued | 2017 | |
dc.description.abstract | En el proceso de conversión energética de un panel FV solo cercadel 15% de la irradiación solar es convertida en energía eléctrica, el resto es irradiación reflejada o se convierte en calor y a su vez en un aumento en la temperatura de operación.El incremento de la temperatura afecta negativamente el flujo libre de electrones. Es por esta razón que es deseable un sistema que monitoree y controle la temperatura de un panel FV;uno de estos sistemases la irrigación de la superficie superior del panel FV utilizando agua como refrigerante. Este trabajo de gradollevó a cabo la implementación de un experimento con una técnica de irrigación basada en un modelo RC predictivo instalada en paneles FV operando con microinversores Enphase 250. El trabajo de grado se desarrolló en tres etapas durante los meses de septiembre y octubre de 2017 en la terraza verde del Edificio de Ingeniería Eléctrica de la Universidad Industrial de Santander (Bucaramanga,Colombia), la primera etapa consistió en la instalación de sensores y el sistema de irrigación; la segunda etapa abordó el desarrollo de los experimentos correspondientes a las dos técnicas de irrigación. Simultáneamente, se tomaron datos de temperatura, irradiación solar y potencia eléctrica generada. La tercera etapa abarcóla comparación de los datos con las mediciones realizadas en el panel FV de referencia (no irrigado) respecto al panel FV con la técnica de irrigación estudiada. Los resultados evidenciaron un beneficio energético superior al implementar la técnica de irrigación predictiva, comparando con un panel fotovoltaico de referencia y un panel fotovoltaico con una técnica de irrigación estática. | |
dc.description.abstractenglish | In the photovoltaic energetic conversion process around of the 15% of the solar irradiation is converted into electric energy, the rest is reflected irradiation or it is converted to heat and in turn in an operating temperature increase. The temperature increase affects negatively the electrons free flux. This is the reason that is desirable a system that permit monitoring and control the photovoltaic temperature, one of these systems is the PV panel's upper surface irrigation using water as a cooler. This degree project carried out the experiment implementation with a cooling technique based in a RC predictive model installed on PV panels operating with Enphase 250 microinverter. The degree project was developed in three stages during September and October of 2017 in the green roof of the Electrical Engineering Building from Industrial University of Santander (Bucaramanga,Colombia), the first stage consisted in the sensors and the cooling system installation; the second stage approached the two cooling technique experiments. Simultaneously, were taken the data of temperature, solar radiation and out electrical power. The third stage reached the data comparison with the reference panel data (not cooling). The results evidenced a higher energy benefit when a predictive cooling technique is implemented, comparing with a reference photovoltaic panel and a photovoltaic panel with a static technique cooling. 3 | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electrónico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/37057 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Electrónica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Irrigación | |
dc.subject | Temperatura | |
dc.subject | Eficiencia | |
dc.subject | Paneles Fv. | |
dc.subject.keyword | Cooling | |
dc.subject.keyword | Temperature | |
dc.subject.keyword | Efficiency | |
dc.subject.keyword | Photovoltaic Panels. | |
dc.title | Mejoramiento de un sistema inteligente de irrigación de paneles fotovoltaicos ubicados sobre techo verde | |
dc.title.english | Improvmentof a photovoltaic inteligentcooling system located on a green roof3 | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 247.78 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 169.7 KB
- Format:
- Adobe Portable Document Format