Tanatocronodiagnostico en humanos basado en espectroscopia de impedancia eléctrica, primera fase

dc.contributor.advisorMiranda Mercado, David Alejandro
dc.contributor.advisorEcheverri Perico, Jorge Humberto
dc.contributor.advisorBarrero Perez, Jaime Guillermo
dc.contributor.authorJara Mora, Jenny Andrea
dc.date.accessioned2024-03-03T17:03:32Z
dc.date.available2008
dc.date.available2024-03-03T17:03:32Z
dc.date.created2008
dc.date.issued2008
dc.description.abstractEl tanatocronodiagnóstico es el término empleado en ciencias forenses para hacer referencia a la determinación del tiempo de muerte. Actualmente existen técnicas empleadas para tanatocronodiagnóstico basadas en el estudio de la evolución cronológica de los fenómenos cadavéricos, que depende de variables físicas y químicas de difícil control, generando investigaciones judiciales tardías. Nuevas técnicas alternativas para realizar tanatocronodiagnóstico se pueden derivar de estudios de las propiedades físicas y químicas de un tejido necrótico, como el presente en procesos de isquemia. La isquemia es el proceso de muerte celular provocado por la obstrucción de flujo sanguíneo y suministro de oxigeno a un tejido, lo cual conduce a cambios bioquímicos que varían las características eléctricas del tejido. Estos cambios se pueden cuantificar con mediciones de resistividad eléctrica compleja. En ciencias biomédicas el espectro de impedancia eléctrica (EIE) es el término empleado para referirse a la resistividad eléctrica compleja. Se ha encontrado una marcada correlación entre el EIE y estados de isquemia, sin embargo, para la aplicación de EIE en tanatocronodiagnóstico se requiere evaluar zonas de medición en el cuerpo y la evolución temporal de la EIE en tejido humano ex-vivo. En este trabajo se reporta el rediseño de un bioimpedanciometro que permite realizar medidas de impeditividad en tejido necrótico, el estudio de cuatro zonas del cuerpo para la evaluación de la evolución temporal de la EIE en tejido post-mortem, y las condiciones necesarias para la medición de resistividad eléctrica compleja.
dc.description.abstractenglishTanatocronodiagnostico is the term used in forensic sciences to do reference to the determination of the time of death. Currently, there are some techniques used for tanatocronodiagnostico based in the study of the chronological evolution of the cadaverous phenomena depend of physical and chemical variables of difficult control, generating late judicial investigations. New alternative techniques to make tanatocronodiagnostico can be derived of studies of the physical and chemical properties of a necrotic tissue, as part of ischemia processes. Ischemia is the process of cellular death caused by the obstruction of sanguine flow and supply of oxygen to a tissue, that which leads to biochemical changes that vary the electric characteristics of the tissue. These changes can be quantified with measurement of complex electric resistivity. Biomedical sciences the spectrum of electric impedance (EIE) it is the term used for the complex electric resistivity. Has been find a correlation between the EIE and ischemia states, however, for the application of EIE in tanatocronodiagnostico is required to evaluate zones of measurement in the body and the temporal evolution of the EIE in dead human tissue. In this inform is reported the redesign of a bioimpedanciometer to make measures of impedivity in necrotic tissue, study of four areas in the body to the evaluation of the temporary of the EIE in post-mortem tissue, and the necessary conditions for the measurement of complex electric resistivity.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Electrónico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/21023
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programIngeniería Electrónica
dc.publisher.schoolEscuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectEspectroscopia de impedancia eléctrica
dc.subjectIsquemia
dc.subjectTanatocronodiagnóstico
dc.subjectImpeditividad eléctrica.
dc.subject.keywordEspectroscopy of Eléctric Impedance
dc.subject.keywordIschemia
dc.subject.keywordTanatocronodiagnóstico
dc.subject.keywordElectric Impedivity
dc.titleTanatocronodiagnostico en humanos basado en espectroscopia de impedancia eléctrica, primera fase
dc.title.englishTanatocronodiagnóstico in human based in espectroscopy of eléctric impedance, first phase. +
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Documento.pdf
Size:
2.49 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
302.55 KB
Format:
Adobe Portable Document Format