Revision de los metodos de monitorizacion de la calidad de la energia electrica
dc.contributor.advisor | Duarte Gualdron, Cesar Antonio | |
dc.contributor.author | Jimenez Rivera, Baisser Antonio | |
dc.contributor.author | Navas Garcia, Edwar Jose | |
dc.date.accessioned | 2024-03-03T04:41:36Z | |
dc.date.available | 2004 | |
dc.date.available | 2024-03-03T04:41:36Z | |
dc.date.created | 2004 | |
dc.date.issued | 2004 | |
dc.description.abstract | En este proyecto tiene como fin realizar una revisión de los métodos de monitorización de la calidad de la energía eléctrica propuestos por la norma CEI 61 000-4-30, teniendo en cuenta las condiciones del sistema eléctrico colombiano y su regulación, con el fin realizar ajustes a los métodos sugeridos para aplicarlos en Colombia. Además, se proyecta plantear una propuesta de norma técnica de medición de la calidad de la energía eléctrica en Colombia, con base en la norma CEI 61 000-4-30, continuando de esta forma con el trabajo iniciado con la propuesta de NTC de medición de armónicos realizado en trabajo de grado previo. Además presenta un marco contextual sobre las normativas y recomendaciones internacionales como son la CEI 61000-4-30 y la IEEE 1159, las cuales hacen referencia a la monitorización de la calidad de la energía eléctrica. también, realiza una revisión de las leyes y normas vigentes en Colombia en cuanto a lo que tiene que ver con la calidad de la energía eléctrica emitidas por los organismo encargados de estas como el ICONTEC, realiza la descripción de los conceptos básicos que corresponden a la terminología usada para describir los fenómenos electromagnéticos que afectan la calidad de la energía eléctrica y conceptos referentes a su monitorización; además de hacer una revisión del estado del arte de los equipos encargados de la monitorización de la calidad de la energía eléctrica, realiza un completo estudio de la agregación de las medidas utilizando el algoritmo del valor eficaz, encontrando los posibles errores que se pueden cometer utilizando este método. Finalmente en un anexo se consigna la propuesta de norma técnica colombiana de técnicas de medición para la monitorización de la calidad de la energía eléctrica, basada en los estudios realizados a lo largo del desarrollo este proyecto, con la finalidad de presentarlo ante el ICOTEC para su estudio y posible aprobación. | |
dc.description.abstractenglish | In this project has as end to carry out a revisions of the methods of monitoring of the power quality proposed by the norm CEI 61 000-4-30, keeping in mind the conditions of the Colombian electric system and their regulation, with the purpose of carrying out adjustments to the methods suggested to apply them in Colombia. Also, plans to think about a proposal of technical norm of mensuration of the power quality in Colombia, with base in the norm CEI 61 000-4-30, continuing this way with the initiate work with the proposal of NTC of measurement of harmonic carried out in work of previous grade. It also presents a contextual mark on the regulatory schemes and international recommendations as they are the CEI 61 000-4-30 and the IEEE 1159, which make reference to the monitoring of the power quality, also, carries out a revision of the laws and effective norms in Colombia as for what has to do with the power quality emitted by the in charge organisms of these as the ICONTEC, carries out the description of the basic concepts that correspond to the used terminology for relating concepts to their monitoring; besides making a revision of the state of the art of the in charge teams of the monitoring of the power quality, carries out a complete study of the aggregation of the measures using the algorithm of the effective value, finding the possible errorres that can be made using this method. Finally in an annex the proposal of norm technical Colombian is consigned of technical of measurement for the monitorizacion of the quality of the electric power, based on the realized studies along the development of this project, with the purpose of presenting it before the ICONTEC for its study and possible approval for this organism. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electricista | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/16705 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Eléctrica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Normas Técnicas | |
dc.subject | Calidad de la energía eléctrica | |
dc.subject | Métodos de medición | |
dc.subject | Monitorización | |
dc.subject | Instrumentos. | |
dc.subject.keyword | Technical norms | |
dc.subject.keyword | power quality | |
dc.subject.keyword | Measurement Methods | |
dc.subject.keyword | Monitoring | |
dc.title | Revision de los metodos de monitorizacion de la calidad de la energia electrica | |
dc.title.english | Revision of the methods of monitoring of the power quality | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |