Estudio experimental para evaluar la resistencia del sistema de reforzamiento de muros en tapia pisada con muros de concreto

dc.contributor.advisorViviescas Jaimes, Álvaro
dc.contributor.authorPico Fonseca, German Arvey
dc.contributor.authorHerrera Rodriguez, Jhon Tylor
dc.date.accessioned2024-03-03T23:16:00Z
dc.date.available2017
dc.date.available2024-03-03T23:16:00Z
dc.date.created2017
dc.date.issued2017
dc.description.abstractSe presentan aquí los resultados del estudio experimental de la respuesta estructural de dos muros en tapia pisada, un muro típico de tapia pisada y otro reforzado con un muro estructural conociendo como deficiencia fundamental que las edificaciones en tapia pisada son altamente vulnerables a diferentes tipos de acciones a las cuales se ven solicitadas a diario estas estructuras. Para realizarles a estos dos prototipos mencionados un análisis mediante el sometimiento de cargas laterales cíclicas en su plano y cargas verticales estáticas simuladas de manera eficiente por los actuadores hidráulicos que están disponibles por la escuela de ingeniería civil en los laboratorio de estructuras de la Universidad Industrial de Santander. Se presenta su proceso constructivo mostrando las diferentes etapas partiendo desde la selección del material, así mismo su respectiva planificación, creación, y desarrollo tomando como parámetros principales las propiedades de los materiales empleados para su construcción. Para la evaluación del reforzamiento del muro en tapia pisada con el muro estructural, se le realizó un análisis de los diferentes parámetros que relacionaron la respuesta estructural del muro reforzado como solución para mejorar la resistencia de un muro típico en tapia pisada analizando como objetivo principal de esta investigación los diferentes parámetros de comparación tomando como prioridad la respuesta de las gráficas fuerza vs desplazamiento y desplazamiento vs tiempo. Desarrollando como resultado positivo un gran aumento en la resistencia estructural, la capacidad de soporte de carga estructural, mostrando una mejora significativa en el tiempo de la carga.
dc.description.abstractenglishWe present here the results of the experimental study of the structural response of two walls in stepped wall, a typical wall of stepped wall and another reinforced with a structural wall knowing as fundamental deficiency that the buildings in stepped wall are highly vulnerable to different types of actions to which these structures are requested daily. To perform these two prototypes an analysis by subjecting cyclic lateral loads in their plane and static vertical loads simulated efficiently by the hydraulic actuators that are available by the school of civil engineering in the structures laboratory of the Industrial University of Santander. Its construction process is presented showing the different stages starting from the selection of the material, as well as its respective planning, creation, and development, taking as main parameters the properties of the materials used for its construction. For the evaluation of the reinforcement of the wall in stepped wall with the structural wall, it was made an analysis of the different parameters that related the structural response of the reinforced wall as a solution to improve the resistance of a typical wall in stepped wall analyzing as main objective of this investigation the different parameters of comparison taking as a priority the response of the graphs force vs displacement and displacement vs time. Developing as a positive result a large increase in structural strength, structural load bearing capacity, showing a significant improvement in load time.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Civil
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/35953
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programIngeniería Civil
dc.publisher.schoolEscuela de Ingeniería Civil
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectTapia Pisada
dc.subjectCarga Cíclica
dc.subjectCargas Estáticas
dc.subjectMuro Estructural.
dc.subject.keywordTapia Pisada
dc.subject.keywordCyclic Loads
dc.subject.keywordStatic Loads
dc.subject.keywordStructural Wall.
dc.titleEstudio experimental para evaluar la resistencia del sistema de reforzamiento de muros en tapia pisada con muros de concreto
dc.title.englishExperimental study to evaluate the resistance of the system of reinforcement of walls in tapia floor with concrete walls.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
346.45 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
3.56 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
170.89 KB
Format:
Adobe Portable Document Format