Diseño experimental de un sistema de amortiguamiento de fluido viscoso con comportamiento lineal
dc.contributor.advisor | Begambre Carrillo, Oscar Javier | |
dc.contributor.advisor | Cruz Hernández, Ricardo Alfredo | |
dc.contributor.author | Orduz Suárez, Carlos Felipe | |
dc.contributor.author | Puentes Tamayo, Jenny Alexndra | |
dc.date.accessioned | 2024-03-03T22:14:01Z | |
dc.date.available | 2015 | |
dc.date.available | 2024-03-03T22:14:01Z | |
dc.date.created | 2015 | |
dc.date.issued | 2015 | |
dc.description.abstract | El propósito del diseño sismo resistente tradicional consiste en crear estructuras capaces de disipar la energía de un sismo por medio del daño en elementos estructurales y no estructurales que no comprometan su estabilidad. De esta forma, aunque se requiera su posterior demolición, se espera que la estructura no colapse debido a un sismo. Por otra parte, existen edificaciones de atención a la comunidad para las que este enfoque no es suficiente, pues además de garantizar su supervivencia se deben reducir los daños causados por sismos. Es por esto que se han desarrollado sistemas para la protección sísmica de edificaciones. Uno de estos sistemas es el de amortiguamiento de fluido viscoso, que reduce los desplazamientos de una estructura sin generar en ella esfuerzos adicionales. El objetivo de este estudio consistió en evaluar la respuesta dinámica de un modelo a escala de un pórtico metálico de dos pisos antes y después de la instalación de un sistema de amortiguamiento de fluido viscoso con comportamiento lineal diseñado y construido por los autores. Se utilizó una mesa vibratoria para generar un movimiento armónico en la base del modelo y se registraron las aceleraciones de ambos pisos. Los resultados de los ensayos arrojaron reducciones de hasta 78,03% de las aceleraciones en el modelo debido a la instalación del sistema de amortiguamiento. | |
dc.description.abstractenglish | The purpose of the traditional seismic resistant design consists in creating structures which can dissipate the energy from an earthquake through the damage of structural and non structural elements without compromising its stability. On this way, although it is required its later demolition, it is expected that the structure does not collapse due to an earthquake. On the other hand, there are community attention edifications for which this approach is not enough, because in addition to guarantee its stability it is necessary to reduce the damages due to earthquakes. For this reason systems for the seismic protection of edifications have been developed. One of these systems is the fluid viscous damping system, which allows to reduce the displacements of a structure without generating additional stresses. The objective of this research was to evaluate the dynamic response of a two-floor metallic frame model before and after the installation of a fluid viscous damping system with linear behavior designed and built by the authors. A vibrating table was used to generate an harmonic movement in the base of the model and they were recorded both of the floors accelerations. The results obtained in the tests show reductions of up to 78,03% of the accelerations in the model by the installations of the damping system. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Civil | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/33376 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Civil | |
dc.publisher.school | Escuela de Ingeniería Civil | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Diseño Sismo Resistente | |
dc.subject | Disipación De Energía | |
dc.subject | Sistema De Protección Sísmica | |
dc.subject | Sistema Pasivo | |
dc.subject | Sistema De Amortiguamiento De Fluido Viscoso. | |
dc.subject.keyword | Seismic Resistant Design | |
dc.subject.keyword | Energy Dissipation | |
dc.subject.keyword | Seismic Protection System | |
dc.subject.keyword | Passive System | |
dc.subject.keyword | Viscous Fluid Damping System. | |
dc.title | Diseño experimental de un sistema de amortiguamiento de fluido viscoso con comportamiento lineal | |
dc.title.english | Experimental design of a fluid viscous damping system with linear behavior | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 184.11 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 258.24 KB
- Format:
- Adobe Portable Document Format