Propuesta de procedimiento para el diseño de la automatización de sistemas de iluminación híbrida en espacios interiores desde un enfoque de mínimo costo financiero
dc.contributor.advisor | Villamizar Mejia, Rodolfo | |
dc.contributor.advisor | Osma Pinto, German Alfonso | |
dc.contributor.advisor | Ordoñez Plata, Gabriel | |
dc.contributor.author | Amado Duarte, Laura Yazmin | |
dc.date.accessioned | 2024-03-04T00:05:40Z | |
dc.date.available | 2018 | |
dc.date.available | 2024-03-04T00:05:40Z | |
dc.date.created | 2018 | |
dc.date.issued | 2018 | |
dc.description.abstract | Este trabajo de investigación define un procedimiento para el dimensionamiento de la alternativa de control de la iluminación eléctrica de sistemas de iluminación híbrida, para espacios seleccionados con características similares a los existentes en el Edificio de Ingeniería Eléctrica, considerando el menor costo financiero total. Este procedimiento consta de ocho (8) pasos secuenciales: (i) Caracterización del espacio (física y lumínica natural), (ii) Caracterización lumínica y de operación de las luminarias del SIH, (iii) Definición de las alternativas de control (cantidad y características técnicas) de potencial aplicación, (iv) Modelado de la iluminación total interior y consumo de energía para cada alternativa de control, (v) Cuantificación de las cantidades mínimas de los componentes requeridos para la implementación de cada alternativa de control, (vi) Definición de la función de costo financiero total por alternativa, (vii) Estimación del costo financiero total de cada alternativa de control y selección de la alternativa de menor costo financiero total y (viii) Construcción del informe de dimensionamiento de la alternativa de control del SIH seleccionada. El procedimiento se aplicó a dos espacios interiores del Edificio de Ingeniería Eléctrica, aula IE305 y Sala de reuniones (piso 5) con iluminación fluorescente, lo que permitió establecer la alternativa de control de menor costo financiero para cada recinto. Tal proceso se basó en el modelado experimental de los sistemas de iluminación de los dos recintos interiores. En total, se consideraron 756 y 5428 alternativas de control para cada recinto, respectivamente; por lo que se debió utilizar softwares especializado, MATLAB y GAMS. | |
dc.description.abstractenglish | This research work presents a procedure for the dimensioning of the electrical lighting control alternative of hybrid lighting systems (HLS), for selected spaces with similar characteristics to existing ones in the Electrical Engineering Building, considering the lower total financial cost. This procedure consists of eight (8) sequential steps: (i) Characterization of the space both in its physical part and in its daylighting, (ii) Lighting and operation characterization of the ILS luminaires, (iii) Definition of the control alternatives (quantity and technical characteristics) of potential application. (iv) Modeling of the total indoor lighting and energy consumption for each control alternative, (v) Quantification of the minimum quantities of the required components for the implementation of each control alternative, (vi) Definition of the total financial cost function by alternative, (vii) Estimation of total financial cost of each control alternative and selection of the alternative of lower total financial cost and (viii) Construction of the dimensioning report of the selected control alternative for the HLS. The procedure was applied to two indoor spaces of Electrical Engineering Building, classroom IE305 (third floor) and meeting room (fifth floor) with an fluorescent lighting system, which allowed stablish the control alternative of lower financial cost for each space. Such a process was based on the experimental modeling of the lighting systems of the two indoor spaces. In total, were considered 756 and 5428 control alternative for each space, respectively, reason why it was necessary to use specialized software, MATLAB y GAMS. 3 | |
dc.description.degreelevel | Maestría | |
dc.description.degreename | Magíster en Ingeniería Electrónica | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/38697 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Maestría en Ingeniería Electrónica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Iluminación Híbrida | |
dc.subject | Experimentación | |
dc.subject | Modelado | |
dc.subject | Alternativa De Control | |
dc.subject | Automatización. | |
dc.subject.keyword | Hybrid Lighting | |
dc.subject.keyword | Experimentation | |
dc.subject.keyword | Modeling | |
dc.subject.keyword | Control Alternative | |
dc.subject.keyword | Automation. | |
dc.title | Propuesta de procedimiento para el diseño de la automatización de sistemas de iluminación híbrida en espacios interiores desde un enfoque de mínimo costo financiero | |
dc.title.english | Proposal of procedure for the design of the automation of hybrid lighting systems in indoor spaces from a minimum financial cost approach 3 | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_bdcc | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Maestria |