Evaluación del comportamiento estructural de anclajes metálicos post-instalados en elementos de concreto para líneas de vida
dc.contributor.advisor | Rico Pradilla, Leocadio | |
dc.contributor.author | Calderón Plata, Catalina | |
dc.contributor.author | Angarita Suarez, Edwing Alexis | |
dc.date.accessioned | 2024-03-03T20:07:10Z | |
dc.date.available | 2013 | |
dc.date.available | 2024-03-03T20:07:10Z | |
dc.date.created | 2013 | |
dc.date.issued | 2013 | |
dc.description.abstract | La creciente tasa de accidentalidad en trabajo en alturas en Colombia conlleva a que se dispongan de reglamentos y de elementos de protección personal como por ejemplo arnés, eslinga y líneas de vida para garantizar la integridad física del trabajador. Las líneas de vida son sistemas certificados debidamente anclados a una estructura, para garantizar la seguridad de los trabajadores al realizar labores en alturas. El Reglamento colombiano de Seguridad para Protección Contra Caídas en Trabajo en Alturas (Resolución número 1409 del 23 de Julio de 2012) define el anclaje como punto seguro al que pueden conectarse equipos personales de protección contra caídas con una resistencia mínima de 5000 lb - 22,2 kN por persona conectada. Los anclajes post instalados de torque controlado, se diseñaron cumpliendo con los parámetros establecido por el Apéndice C-D del Reglamento colombiano de Construcción Sismo Resistente (NSR-10). Las resistencias de los anclajes están definidas por ecuaciones en el apéndice C - D de la NSR-10, pero en el caso de la resistencia a la extracción por deslizamiento por tracción del anclaje, la NSR-10 establece que debe determinarse siguiendo los procedimientos establecidos por el código ACI 355.2. Al realizar estos ensayos, se obtuvieron importantes deducciones, como que la resistencia por extracción por deslizamiento no depende de la distancia al borde a la cual se encuentre instalado el anclaje, que solo depende del diámetro del anclaje y de la profundidad efectiva de embebido; también que el procedimiento de instalación es fundamental para que la resistencia a la extracción por deslizamiento sea la adecuada. | |
dc.description.abstractenglish | The increasing rate of accident in working at heights in Colombia this carries that prepare of regulations and of elements or personal protection as for example harness, sling and lifelines to guarantee the physical integrity of the worker. Lifelines are certified systems they are duly anchored to structure in order to guarantee safety of workers when working at heights. The Colombian Regulation of Security to protect employees against accidents at heights (Resolución número 1409 del 23 de Julio de 2012) define the anchor as a sure point to which can connect personal protective equipment against falls with a minimum strength of 5000 lb - 22.2 kN by connected person. The anchors are designed carrying with the parameters established by the appendix C-D of the NSR-10, but in the case of the resistance to the extraction by traction slip of anchor, the NSR-10 establishes that it must be determined following the procedures proposed by ACI 355.2. On having realized these tests, there are obtained important deductions, as which the resistance for extraction for slide does not depend on the distance to the edge to which one finds installed the anchorage, which alone depends on the diameter of the anchorage and on the effective depth of absorbed; also that the procedure of installation is fundamental in order that the resistance to the extraction for slide is the suitable one. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Civil | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/29101 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Civil | |
dc.publisher.school | Escuela de Ingeniería Civil | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Trabajo En Alturas | |
dc.subject | Líneas De Vida | |
dc.subject | Anclaje Post- Instalado | |
dc.subject | Anclaje De Expansión. | |
dc.subject.keyword | Working At Heights | |
dc.subject.keyword | Life Line | |
dc.subject.keyword | Post Installed Anchor | |
dc.subject.keyword | Expansión Anchor. | |
dc.title | Evaluación del comportamiento estructural de anclajes metálicos post-instalados en elementos de concreto para líneas de vida | |
dc.title.english | Evaluation of the structural behavior of metallic anchors post-installed in elements of concrete for lifelines3 | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 114.95 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 355.83 KB
- Format:
- Adobe Portable Document Format