Diseño y construcción de una máquina de fatiga automatizada para el estudio de materiales con memoria de forma

dc.contributor.advisorNino Delgado, Romulo
dc.contributor.advisorForero Gomez, Luis Emilio
dc.contributor.authorOrejuela Sandoval, Leandro Esteban
dc.date.accessioned2024-03-03T16:11:56Z
dc.date.available2006
dc.date.available2024-03-03T16:11:56Z
dc.date.created2006
dc.date.issued2006
dc.description.abstractEl objetivo de este proyecto es dotar al laboratorio de biomateriales de la escuela de ingeniería Metalúrgica y ciencia de Materiales de la Universidad Industrial de Santander, de una maquina de ensayos para el estudio de materiales con memoria de forma utilizados en implantes cardiovasculares. Con la maquina se podrá establecer el comportamiento de los materiales con memoria de forma (microtubos) al ser sometidos a cargas cíclicas, presiones internas alternativas con frecuencia y presión similares a las del corazón y condiciones térmicas desde el ambiente hasta temperaturas extremas (aproximadamente 100 C). La información obtenida se da en base a la variación de algunas de sus propiedades físicas como deformación, esfuerzos, cambio en la resistividad (/), cambio en la resistencia (R/R) entre otras que serán sensadas y registradas todo el tiempo a través de un sistema de control y adquisición de datos mediante la aplicación de un software desarrollado paralelamente en un proyecto de grado de un estudiante de Ingeniería electrónica y cuyo análisis podrá determinar los cambios en la estructura interna del material o cambios de fase. La maquina se diseñó y construyo utilizando como soporte de diseño paquetes CAD (Solid Works) y CAE (Cosmos) obteniendo una maquina que permitirá al laboratorio de biomateriales continuar con su proceso investigativo en el campo de los materiales utilizados en implantes cardiovasculares cumpliendo con los siguientes requerimientos: 1. Permitir someter a los microtubos a un estado de tensión por cargas fluctuantes con un rango de selección 100 a 2400 Newton y una frecuencia determinada según se requiera. 2. Permitir presurizar internamente los microtubos simulando la presión alternativa ejercida por el corazón con una frecuencia máxima de 120 cpm. 3. Mantener al microtubo en las condiciones determinadas de temperatura en un rango de selección desde la temperatura ambiente hasta aproximadamente 100 C
dc.description.abstractenglishThe objective of this project is to endow the biomaterials lab of school metallurgy engineering of the Industrial University of Santander of a test machine to study Shape memory materials used in cardiovascular implants. With the machine anyone would determine the behaviors of the Shape memory materials, when being undergone to cyclic load, alternative internal pressures with pressure and frequencies similar to the heart´s, and thermal conditions from environmental temperatures to extreme temperatures (about 100 ºC). The outcome is based on physical the variation of some physical properties, such as deformation, stress, resistivity changes (/), resistance changes (R/R), among others that will be registered all the time using a control and acquisition data system, through the application of a software parallelly developed in a degree work by a electronic engineering student. This software determine the changes in the inner structure of the material or phase changes. The machine was designed and built using software like CAD (Solid Works) y CAE (Cosmos) getting a machine that permits Biomaterial lab continue with its research process in cardiovascular implants, performing the next features: 1. Undergo the microtubes to tension state by fluctuating load with a range of selection between 100 and 2400 Newton and a determined frequency. 2. Pressurize alternatively the microtubes with pressures similar to the heart´s alternative pressure, with a maximun frequency of 120 cpm. 3. Maintain the microtube in conditions of temperature between a range of selection of environmental temperature up to 100 ºC.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Mecánico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/18983
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programIngeniería Mecánica
dc.publisher.schoolEscuela de Ingeniería Mecánica
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectMaquina de fatiga
dc.subjectMateriales con memoria
dc.subjectStent
dc.subject.keywordFatigue machine
dc.subject.keywordShape memory material
dc.subject.keywordStent
dc.titleDiseño y construcción de una máquina de fatiga automatizada para el estudio de materiales con memoria de forma
dc.title.englishDesign and building of automated fatigue machine for shape memory material study
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Documento.pdf
Size:
5.74 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
298.75 KB
Format:
Adobe Portable Document Format