dc.date.issued | 2006 | |
dc.description.abstract | El objetivo de este proyecto es dotar al laboratorio de biomateriales de la escuela de ingeniería Metalúrgica y ciencia de Materiales de la Universidad Industrial de Santander, de una maquina de ensayos para el estudio de materiales con memoria de forma utilizados en implantes cardiovasculares. Con la maquina se podrá establecer el comportamiento de los materiales con memoria de forma (microtubos) al ser sometidos a cargas cíclicas, presiones internas alternativas con frecuencia y presión similares a las del corazón y condiciones térmicas desde el ambiente hasta temperaturas extremas (aproximadamente 100 C). La información obtenida se da en base a la variación de algunas de sus propiedades físicas como deformación, esfuerzos, cambio en la resistividad (/), cambio en la resistencia (R/R) entre otras que serán sensadas y registradas todo el tiempo a través de un sistema de control y adquisición de datos mediante la aplicación de un software desarrollado paralelamente en un proyecto de grado de un estudiante de Ingeniería electrónica y cuyo análisis podrá determinar los cambios en la estructura interna del material o cambios de fase. La maquina se diseñó y construyo utilizando como soporte de diseño paquetes CAD (Solid Works) y CAE (Cosmos) obteniendo una maquina que permitirá al laboratorio de biomateriales continuar con su proceso investigativo en el campo de los materiales utilizados en implantes cardiovasculares cumpliendo con los siguientes requerimientos: 1. Permitir someter a los microtubos a un estado de tensión por cargas fluctuantes con un rango de selección 100 a 2400 Newton y una frecuencia determinada según se requiera. 2. Permitir presurizar internamente los microtubos simulando la presión alternativa ejercida por el corazón con una frecuencia máxima de 120 cpm. 3. Mantener al microtubo en las condiciones determinadas de temperatura en un rango de selección desde la temperatura ambiente hasta aproximadamente 100 C | |
dc.description.abstractenglish | The objective of this project is to endow the biomaterials lab of school metallurgy engineering of the Industrial University of Santander of a test machine to study Shape memory materials used in cardiovascular implants. With the machine anyone would determine the behaviors of the Shape memory materials, when being undergone to cyclic load, alternative internal pressures with pressure and frequencies similar to the heart´s, and thermal conditions from environmental temperatures to extreme temperatures (about 100 ºC). The outcome is based on physical the variation of some physical properties, such as deformation, stress, resistivity changes (/), resistance changes (R/R), among others that will be registered all the time using a control and acquisition data system, through the application of a software parallelly developed in a degree work by a electronic engineering student. This software determine the changes in the inner structure of the material or phase changes. The machine was designed and built using software like CAD (Solid Works) y CAE (Cosmos) getting a machine that permits Biomaterial lab continue with its research process in cardiovascular implants, performing the next features: 1. Undergo the microtubes to tension state by fluctuating load with a range of selection between 100 and 2400 Newton and a determined frequency. 2. Pressurize alternatively the microtubes with pressures similar to the heart´s alternative pressure, with a maximun frequency of 120 cpm. 3. Maintain the microtube in conditions of temperature between a range of selection of environmental temperature up to 100 ºC. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Mecánico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/18983 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Ingeniería Mecánica | |
dc.publisher.school | Escuela de Ingeniería Mecánica | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Maquina de fatiga | |
dc.subject | Materiales con memoria | |
dc.subject | Stent | |
dc.subject.keyword | Fatigue machine | |
dc.subject.keyword | Shape memory material | |
dc.subject.keyword | Stent | |
dc.title | Diseño y construcción de una máquina de fatiga automatizada para el estudio de materiales con memoria de forma | |
dc.title.english | Design and building of automated fatigue machine for shape memory material study | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |