Determinación de metales pesados en muestras de agua provenientes de las sedes de la Universidad Industrial de Santander del área metropolitana

dc.contributor.advisorMeléndez Reyes, Ángel Manuel
dc.contributor.advisorFlórez Suárez, María Alejandra
dc.contributor.authorOrdóñez Vargas, Diego Iván
dc.date.accessioned2023-04-06T12:53:44Z
dc.date.available2023
dc.date.available2023-04-06T12:53:44Z
dc.date.created2019
dc.date.issued2019
dc.description.abstractActualmente el deterioro del medio ambiente ha llevado a tomar medidas de control y vigilancia de los metales presentes en el agua potable que afectan la salud pública. Una alternativa económica a los métodos convencionales utilizados para la determinación de metales pesados a nivel traza es la voltamperometría de redisolución anódica (ASV). Con la finalidad de contribuir a determinar la calidad del agua potable de los bebederos de las sedes del área metropolitana de la Universidad Industrial de Santander, en esta investigación se usó la ASV para determinar la concentración de cationes metálicos en el agua que puedan ser potencialmente tóxicos: Cu, Zn, Cd y Pb. La sensibilidad y la ventana de potencial para realizar el análisis de ASV se incrementó agregando 10-3 M HgCl2, con la finalidad de formar micro amalgamas durante la etapa de preconcentración. Se estudió la influencia del material de electrodo, encontrando que el carbón vítreo presenta varias ventajas sobre el electrodo de pasta de carbono, principalmente en la repetitividad (precisión) de la determinación. Además, se estudió el tiempo de preconcentración en la determinación de los metales pesados. Se elaboraron curvas de calibración para cada metal en un intervalo de concentración entre 0.1 ppm a 1.5 ppm. De esta manera se logró detectar cualitativa y cuantitativamente la presencia de Zn2+, Cd2+, Pb2+ y Cu2+. La cantidad de los metales encontrados están por debajo de los límites establecidos por el Ministerio de Ambiente; sin embargo, en uno de los bebederos se encontró la presencia de todos los metales pesados determinados. Indirectamente se determinó la presencia de materia orgánica en las aguas.
dc.description.abstractenglishCurrently the deterioration of the environment has led to prioritization of water quality monitoring of metals present in drinking water, because affect the public health. An economical alternative to the conventional methods used for the determination of trace level heavy metals is the anodic stripping voltammetry (ASV). In order to contribute to determinate the water quality of drinking fountains of metropolitan campuses of the Universidad Industrial de Santander, herein is used the ASV to determine the metal cations concentration in water that can be potentially toxic: Cu, Zn, Cd and Pb. The sensitivity and the potential range to perform the ASV were increased by adding 10-3 M HgCl2 to the solution, in order to forming micro amalgams during the preconcentration step. The influence of the electrode material was studied, finding that glassy carbon electrode has several advantages over carbon paste electrode, mainly in the repeatability (precision) of the determination. In addition, the preconcentration time on the determination of heavy metals was studied. Calibration curves were made for each metal in a concentration range between 0.1 ppm to 1.5 ppm. Thus, it was possible to detect qualitatively and quantitatively the presence of Zn2+, Cd2+, Pb2+ y Cu2+. The amount of metals found is below upper the limits established by the Ministerio de Ambiente; however, in one of the drinking fountains all the determined heavy metals was found. Indirectly the presence of organic matter was determined in the water.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Metalúrgico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/13688
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Metalúrgica
dc.publisher.schoolEscuela de Ingeniería Metalúrgica y Ciencia de Materiales
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectVoltamperometría de redisolución anódica
dc.subjectMetales traza
dc.subjectElectrodos de carbono
dc.subjectVigilancia y evaluación de la calidad del agua potable
dc.subject.keywordAnodic Stripping Voltammetry
dc.subject.keywordTrace Metals
dc.subject.keywordCarbon-Based Electrodes
dc.subject.keywordMonitoring Drinking Water Quality
dc.titleDeterminación de metales pesados en muestras de agua provenientes de las sedes de la Universidad Industrial de Santander del área metropolitana
dc.title.englishDetermination of heavy metals in water samples from the metropolitan campuses of the Universidad Industrial de Santander
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.type
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
231.32 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
1.71 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
182.91 KB
Format:
Adobe Portable Document Format