Desempeño energético del sistema fotovoltaico del Edificio de la Escuela de Ingenierías Eléctrica, Electrónica y de Telecomunicaciones a 2023
dc.contributor.advisor | Osma Pinto, German Alfonso | |
dc.contributor.author | Saenz Niño, Karen Daniela | |
dc.contributor.author | Guarín Puentes, Duvan Andrés | |
dc.contributor.evaluator | Cardenas Rangel, Jorge Luis | |
dc.contributor.evaluator | Caballero Peña, Juan Diego | |
dc.date.accessioned | 2024-08-22T12:24:15Z | |
dc.date.available | 2024-08-22T12:24:15Z | |
dc.date.created | 2024-08-21 | |
dc.date.embargoEnd | 2026-09-26 | |
dc.date.issued | 2024-08-21 | |
dc.description.abstract | Este trabajo de grado evalúa el rendimiento energético de un sistema fotovoltaico en un edificio universitario. El SFV de la E3T se encuentra situado en la terraza del quinto piso y está compuesto por 43 módulos solares fotovoltaicos monocristalinos y policristalinos fijos con orientaciones de 10° sur-norte, 10° norte-sur y 0. El objetivo principal de este trabajo es evaluar el desempeño energético del sistema fotovoltaico durante seis meses, utilizando datos meteorológicos y parámetros eléctricos. Para alcanzar este objetivo, se instaló un sistema de monitoreo que captura variables necesarias para el análisis del desempeño. Este sistema incluye dataloggers, piranómetros y termocuplas, que facilitan la lectura, análisis y procesamiento de datos de potencia, energía, temperatura operativa e irradiación solar. Además, se construyó una base de datos integral que recopila las variables monitoreadas, sobre la cual se realizaron evaluaciones detalladas de los indicadores de desempeño específicos del sistema fotovoltaico en estudio. El análisis de los datos recopilados durante un período de seis meses evidenció una alta captación de irradiancia, lo cual se traduce en una producción óptima de energía eléctrica a partir de la energía solar. El análisis de datos recopilados, evidenció una alta captación de irradiancia y una producción óptima de energía solar, con un rendimiento superior al 70%. Los indicadores de rendimiento específico y de referencia corroboraron esta eficiencia, demostrando una relación efectiva entre la captación de irradiancia y su conversión en energía útil. Estos resultados refuerzan la efectividad del SFV en la E3T. | |
dc.description.abstractenglish | This thesis evaluates the energy performance of a photovoltaic system in a university building. The PV system at E3T is located on the rooftop of the fifth floor of the school building and consists of 43 fixed monocrystalline and polycrystalline solar modules with orientations of 10° south-north, 10° north-south, and 0°. The main objective of this study is to assess the energy performance of the photovoltaic system in the Electrical Engineering Building over a six-month period, using meteorological data and electrical parameters. To achieve this goal, a monitoring system was deployed to capture the variables necessary for performance analysis. This system relied on the installation of devices such as dataloggers, pyranometers, and thermocouples, whose operation guided the establishment of a methodology for data reading, analysis, and processing related to power, energy, operating temperature, and solar irradiance. This strategy was chosen to optimize resources and make the most of the equipment already available at E3T, thus minimizing operational costs and promoting efficient management of institutional resources. Additionally, a comprehensive database was built to collect the monitored variables, upon which detailed evaluations of specific performance indicators of the photovoltaic system under study were conducted. The analysis of the collected data revealed a high irradiance capture and optimal solar energy production, with a performance exceeding 70%. The specific and reference performance indicators corroborated this efficiency, demonstrating an effective relationship between irradiance capture and its conversion into useful energy. These results reinforce the effectiveness of the PV system at E3T. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Electricista | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/43839 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
dc.publisher.program | Ingeniería Eléctrica | |
dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-NoComercial 2.5 Colombia (CC BY-NC 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Datalogger | |
dc.subject | eficiencia | |
dc.subject | energías renovables | |
dc.subject | irradiancia | |
dc.subject | piranómetro | |
dc.subject | termocupla | |
dc.subject.keyword | Datalogger | |
dc.subject.keyword | efficiency | |
dc.subject.keyword | pyranometer | |
dc.subject.keyword | renewable energies | |
dc.subject.keyword | thermocouple | |
dc.subject.keyword | irradiance | |
dc.title | Desempeño energético del sistema fotovoltaico del Edificio de la Escuela de Ingenierías Eléctrica, Electrónica y de Telecomunicaciones a 2023 | |
dc.title.english | Energy performance of the photovoltaic system of the School of Electrical, Electronic and Telecommunications Engineering building to 2023 | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 5 of 5
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 115.72 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 185.05 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Apéndices.pdf
- Size:
- 140.85 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta de confidencialidad.pdf
- Size:
- 120.64 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: