Medición del índice de consistencia cervical en el primer y segundo trimestre en gestantes con embarazo único, residentes del área metropolitana de Bucaramanga como predictor de parto pretérmino espontáneo

dc.contributor.advisorBecerra Mojica, Carlos Hernán
dc.contributor.advisorOsma Zambrano, Sonia Esperanza
dc.contributor.authorHerrera Flórez, Diana Marcela
dc.contributor.evaluatorGutiérrez Sánchez, Luz Ángela
dc.contributor.evaluatorManrique Hernández, Édgar Fabián
dc.date.accessioned2025-05-22T21:05:35Z
dc.date.available2025-05-22T21:05:35Z
dc.date.created2025-05-19
dc.date.issued2025-05-19
dc.description.abstractIntroducción: Definido como el parto que ocurre antes de las 37 semanas, es un síndrome multifactorial. El parto pretérmino es un problema de salud pública con impacto demostrado en la salud neonatal e infantil, es la cuarta causa de discapacidad a corto y largo plazo lo que representa una alta carga social. La predicción permite emprender acciones tempranas para evitar llegar al parto prematuro y ubicar a la gestante en el mejor escenario de atención. Métodos: Estudio analítico de cohorte prospectiva. Se incluyeron gestantes con embarazo único que asistieron a toma de ecografía y a quienes se realizó la medición del índice de consistencia cervical (ICC) en dos momentos, el primero entre la semana 11 – 13+6 semanas y el segundo entre las 18 y 24 semanas de embarazo. El protocolo fue aprobado por los comités de ética de las instituciones participantes. Resultados: 140 participantes fueron analizadas que completaron ambas mediciones. La mediana del ICC fue 0.81 RI=[0.77-0.86] en primer trimestre y de 0.75, RI=[0.70-0.79] en el segundo trimestre, siendo esta diferencia estadísticamente significativa p<0.001. La media de la longitud cervical en el primer trimestre fue de 34.28 mm, DE=3.67; comparado con el segundo trimestre de 37.08 mm DE=5.37 y valor p<0.001. La media del diámetro anteroposterior en primer trimestre fue de 32.12mm DE=3.25 respecto al segundo trimestre 33.95mm DE=4.31 y valor p<0.001. Conclusión: Este estudio mostró una disminución en la consistencia del cérvix con un comportamiento lineal del ICC desde el primer hasta el segundo trimestre. La longitud cervical aumenta entre primer y segundo trimestre. Estos hallazgos sugieren que el ICC es una herramienta útil para evaluar el ablandamiento cervical en etapas tempranas de la gestación, demostrando una alta reproducibilidad y fiabilidad tanto intraobservador como interobservador.
dc.description.abstractenglishIntroduction: Preterm birth, defined as delivery before 37 weeks of gestation, is a multifactorial syndrome and a major public health concern with a well-established impact on neonatal and childhood health. It is the fourth leading cause of both short- and long-term disability, representing a significant social burden. Early prediction allows for timely interventions to prevent preterm birth and to ensure optimal care for the pregnant patient. Methods: This was a prospective analytical cohort study. Pregnant women with singleton gestations who attended ultrasound examinations were included, and their cervical consistency index (CCI) was measured at two time points: the first between 11 and 13+6 weeks of gestation and the second between 18 and 24 weeks. The study protocol was approved by the ethics committees of the participating institutions. Results: A total of 140 participants who completed both measurements were analyzed. The median CCI was 0.81 (IQR = [0.77–0.86]) in the first trimester and 0.75 (IQR = [0.70–0.79]) in the second trimester, with a statistically significant difference (p < 0.001). The mean cervical length in the first trimester was 34.28 mm (SD = 3.67), compared to 37.08 mm (SD = 5.37) in the second trimester (p < 0.001). The mean anteroposterior diameter was 32.12 mm (SD = 3.25) in the first trimester and 33.95 mm (SD = 4.31) in the second trimester (p < 0.001). Conclusion: This study demonstrated a decrease in cervical consistency with a linear pattern of CCI from the first to the second trimester. Cervical length increased between the first and second trimesters. These findings suggest that CCI is a useful tool for assessing cervical softening in the early stages of pregnancy, demonstrating high intra- and inter-observer reproducibility and reliability.
dc.description.degreelevelEspecialización
dc.description.degreenameEspecialista en Ginecología y Obstetricia
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/45604
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Salud
dc.publisher.programEspecialización en Ginecología y Obstetricia
dc.publisher.schoolEscuela de Medicina
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectParto pretérmino
dc.subjectÍndice de consistencia cervical
dc.subjectLongitud cervical
dc.subject.keywordPre-Term Birth
dc.subject.keywordCervical Consistency Index
dc.subject.keywordCervical Length
dc.titleMedición del índice de consistencia cervical en el primer y segundo trimestre en gestantes con embarazo único, residentes del área metropolitana de Bucaramanga como predictor de parto pretérmino espontáneo
dc.title.englishMeasurement of the Cervical Consistency Index in the First and Second Trimesters in Pregnant Women with Singleton Gestation Residing in the Metropolitan Area of Bucaramanga as a Predictor of Spontaneous Preterm Birth
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Especialización
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Documento.pdf
Size:
1.21 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
291.01 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
143.86 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: