Estudio de la detección precoz de cáncer de cuello uterino por medio del análisis de la respuesta fluorescente natural en muestra ex-vivo

dc.contributor.advisorGuerrero Bermudez, Jader Enrique
dc.contributor.authorMahecha Capacho, Diego Rolando
dc.date.accessioned2024-03-03T16:12:41Z
dc.date.available2006
dc.date.available2024-03-03T16:12:41Z
dc.date.created2006
dc.date.issued2006
dc.description.abstractEn el mundo el cáncer de cérvix o cáncer de cuello uterino es la segunda causa de muerte más frecuente entre las mujeres después del carcinoma de glándula mamaria. Es un problema de salud pública que afecta a la mujer, especialmente en los países en vía de desarrollo; en un primer paso, para dar respuesta a nuevas metodologías de diagnóstico se desarrollo una metodología para tal fin. Al intentar presentar un método específico para establecer el diagnóstico de lesiones precursoras y cáncer de cérvix, se consideraron diversas metodologías de estudio del análisis de la respuesta espectral fluorescente natural en muestras ex-vivo y sin el uso de fluorocromos; la primera se centra en el estudio microscópico de fluorescencia se realizaron estudios bajo la microscopia de fluorescencia y la segunda en el análisis de la respuesta de espectrometría. La microscopía de fluorescencia y la detección precoz de cáncer de cuello uterino en muestras ex-vivo sin uso de fluorocromos, fue un método en donde se pretendía encontrar alguna respuesta a la excitación con luz ultravioleta (UV) en las imágenes obtenidas. Luego de innumerables pruebas con el microscopio se encontró que mediante esta técnica no era posible mostrar alguna diferencia entre una imagen obtenida de una muestra negativa y una positiva. La espectroscopía uv-visible y la detección precoz de cáncer de cuello uterino en muestras ex-vivo sin uso de fluorocromos, se realizó mediante reflectancia difusa y transmitancia, en ambos casos al obtener los espectros para su análisis, se encontró que no se presentaban características distintivas, aún con análisis de redes neuronales backpropagation. La conclusión del trabajo de investigación es que mediante la fluorescencia natural de las muestras de cuello uterino, no es posible proponer técnicas para la diferenciación entre una placa negativa y una con lesión precursora o con cáncer de cérvix.
dc.description.abstractenglishIn the world the cervical cancer or cancer of uterine neck is the most frequent second reason of death between the women after the carcinoma of mammary gland. It's a problem of health public that affects the woman, especially in the countries in route of development; in the first step, to give response to new methodologies of diagnosis I develop a methodology for such a purpose. On having tried to present a specific method to establish the diagnosis of cervical cancer, they were considered to be diverse methodologies of study of the analysis of the spectral fluorescent natural response in samples ex-vivo and without the use of fluorocromos; the first one centre on the microscopic study of fluorescence studies were realized under the microscopy of fluorescence and the second one in the analysis of the response of spectroscopy. The microscopy of fluorescence and the detection of cervical cancer in samples ex-vivo without use of fluorocromos, it was a method where one was trying to find some response to the excitation with ultraviolet light (UV) in the obtained images. After innumerable proofs with the microscope one thought that by means of this technology it was not possible to show any difference between an image obtained of a negative sample and positive one. The uv-visible spectroscopy it was realized by means of reflectancia diffuse and transmitancia, in both cases on having obtained the spectra for your analysis, one thought that they were not presenting distinctive characteristics, yet with analysis of neural network (backpropagation). The conclusion of the work of investigation is that by means of the natural fluorescence of the samples of uterine neck, it's not possible to propose technologies for the differentiation between a negative plate and one with cervical cancer.
dc.description.degreelevelMaestría
dc.description.degreenameMagíster en Ingeniería Electrónica
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/19028
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programMaestría en Ingeniería Electrónica
dc.publisher.schoolEscuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectfluorescencia
dc.subjectRespuesta espectral
dc.subjectCáncer de cérvix
dc.subjectMicroscopio de fluorescencia
dc.subject.keywordfluorescence
dc.subject.keywordSpectral response
dc.subject.keywordCervical cancer
dc.subject.keywordMicroscope of fluorescence
dc.subject.keywordSpectrophotometer
dc.titleEstudio de la detección precoz de cáncer de cuello uterino por medio del análisis de la respuesta fluorescente natural en muestra ex-vivo
dc.title.englishStudy of the detection of cancer of uterine neck by means of the analysis of the fluorescent natural response in samples ex-vivo2
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_bdcc
dc.type.localTesis/Trabajo de grado - Monografía - Maestria
Files
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Documento.pdf
Size:
1.45 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
92.78 KB
Format:
Adobe Portable Document Format